Correction and characterization of scattered events in three-dimensional PET using scanners with retractable septa

Simon R Cherry, S. R. Meikle, E. J. Hoffman

Research output: Contribution to journalArticle

32 Citations (Scopus)

Abstract

Large sensitivity increases are realized in positron emission tomography when the interplane septa are removed and all lines of response acquired. Unfortunately, three-dimensional acquisition results in a large increase in scatter fraction which prevents accurate quantitation. By acquiring short two-dimensional scans prior to three-dimensional ones, scatter distributions can be estimated from differences between lines of response common to both datasets. This initial scatter distribution can be further modified to approximate scatter in the entire three-dimensional dataset. The method was validated with phantom measurements in which absolute activity concentrations were known in all compartments. Following scatter correction, a four- compartment phantom that was nonuniform in activity and density, both axially and transaxially, gave activity concentrations of 0.45 ± 0.02, 0.31 ± 0.02, 0.01 ± 0.01 and 0.01 ± 0.01 μCi/cc for compartments containing 0.43, 0.29, 0.0 (air) and 0.0 (water) μCi/cc, respectively. Thus, scatter distributions for complex sources can be estimated from image data without lengthy MonteCarlo simulations. When activity distributions vary slowly with time, this method can be used to correct for scatter in three-dimensional patient studies.

Original languageEnglish (US)
Pages (from-to)671-678
Number of pages8
JournalJournal of Nuclear Medicine
Volume34
Issue number4
StatePublished - 1993

Fingerprint

Positron-Emission Tomography
Air
Water
Datasets

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Correction and characterization of scattered events in three-dimensional PET using scanners with retractable septa. / Cherry, Simon R; Meikle, S. R.; Hoffman, E. J.

In: Journal of Nuclear Medicine, Vol. 34, No. 4, 1993, p. 671-678.

Research output: Contribution to journalArticle

@article{21caf2a6c1694fff8fc620d2a612df2d,
title = "Correction and characterization of scattered events in three-dimensional PET using scanners with retractable septa",
abstract = "Large sensitivity increases are realized in positron emission tomography when the interplane septa are removed and all lines of response acquired. Unfortunately, three-dimensional acquisition results in a large increase in scatter fraction which prevents accurate quantitation. By acquiring short two-dimensional scans prior to three-dimensional ones, scatter distributions can be estimated from differences between lines of response common to both datasets. This initial scatter distribution can be further modified to approximate scatter in the entire three-dimensional dataset. The method was validated with phantom measurements in which absolute activity concentrations were known in all compartments. Following scatter correction, a four- compartment phantom that was nonuniform in activity and density, both axially and transaxially, gave activity concentrations of 0.45 ± 0.02, 0.31 ± 0.02, 0.01 ± 0.01 and 0.01 ± 0.01 μCi/cc for compartments containing 0.43, 0.29, 0.0 (air) and 0.0 (water) μCi/cc, respectively. Thus, scatter distributions for complex sources can be estimated from image data without lengthy MonteCarlo simulations. When activity distributions vary slowly with time, this method can be used to correct for scatter in three-dimensional patient studies.",
author = "Cherry, {Simon R} and Meikle, {S. R.} and Hoffman, {E. J.}",
year = "1993",
language = "English (US)",
volume = "34",
pages = "671--678",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "4",

}

TY - JOUR

T1 - Correction and characterization of scattered events in three-dimensional PET using scanners with retractable septa

AU - Cherry, Simon R

AU - Meikle, S. R.

AU - Hoffman, E. J.

PY - 1993

Y1 - 1993

N2 - Large sensitivity increases are realized in positron emission tomography when the interplane septa are removed and all lines of response acquired. Unfortunately, three-dimensional acquisition results in a large increase in scatter fraction which prevents accurate quantitation. By acquiring short two-dimensional scans prior to three-dimensional ones, scatter distributions can be estimated from differences between lines of response common to both datasets. This initial scatter distribution can be further modified to approximate scatter in the entire three-dimensional dataset. The method was validated with phantom measurements in which absolute activity concentrations were known in all compartments. Following scatter correction, a four- compartment phantom that was nonuniform in activity and density, both axially and transaxially, gave activity concentrations of 0.45 ± 0.02, 0.31 ± 0.02, 0.01 ± 0.01 and 0.01 ± 0.01 μCi/cc for compartments containing 0.43, 0.29, 0.0 (air) and 0.0 (water) μCi/cc, respectively. Thus, scatter distributions for complex sources can be estimated from image data without lengthy MonteCarlo simulations. When activity distributions vary slowly with time, this method can be used to correct for scatter in three-dimensional patient studies.

AB - Large sensitivity increases are realized in positron emission tomography when the interplane septa are removed and all lines of response acquired. Unfortunately, three-dimensional acquisition results in a large increase in scatter fraction which prevents accurate quantitation. By acquiring short two-dimensional scans prior to three-dimensional ones, scatter distributions can be estimated from differences between lines of response common to both datasets. This initial scatter distribution can be further modified to approximate scatter in the entire three-dimensional dataset. The method was validated with phantom measurements in which absolute activity concentrations were known in all compartments. Following scatter correction, a four- compartment phantom that was nonuniform in activity and density, both axially and transaxially, gave activity concentrations of 0.45 ± 0.02, 0.31 ± 0.02, 0.01 ± 0.01 and 0.01 ± 0.01 μCi/cc for compartments containing 0.43, 0.29, 0.0 (air) and 0.0 (water) μCi/cc, respectively. Thus, scatter distributions for complex sources can be estimated from image data without lengthy MonteCarlo simulations. When activity distributions vary slowly with time, this method can be used to correct for scatter in three-dimensional patient studies.

UR - http://www.scopus.com/inward/record.url?scp=0027513305&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027513305&partnerID=8YFLogxK

M3 - Article

VL - 34

SP - 671

EP - 678

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 4

ER -