Abstract
Objective: We evaluated implanted rat mammary adenocarcinoma tumors during a 5-week period using ultrasound, computed tomography (CT), and histology. Materials and Methods: Contrast-enhanced ultrasound with a destruction- replenishment imaging scheme was used to derive estimates of blood volume and flow. These ultrasound-derived measures of microvascular physiology were compared with contrast-enhanced CT-derived measures of perfusion and vascular volume made by the Mullani-Gould formula and Patlak analysis, respectively. Results: The tumor cross-sectional area and necrotic core cross-sectional area determined by the 3 methods were correlated (r2 > 0.8, P < 0.001, n = 15). The spatial integral of perfusion estimated by CT correlated with the spatial integral of flow from ultrasound (P < 0.05). The contrast-enhanced tumor area calculated from the ultrasound analysis was highly correlated with the contrast-enhanced area estimated by CT images (r2 = 0.89, P < 0.001, n = 15). However, the fraction of the tumor area enhanced by the CT contrast agent was significantly larger than either the fraction enhanced by ultrasound contrast agent or than the viable area as estimated from histology slides. Conclusion: Destruction-replenishment ultrasound provides valuable information about the spatial distribution of blood flow and vascular volume in tumors and ultrasound analysis compares favorably with a validated contrast-enhanced CT method.
Original language | English (US) |
---|---|
Pages (from-to) | 134-147 |
Number of pages | 14 |
Journal | Investigative Radiology |
Volume | 40 |
Issue number | 3 |
DOIs | |
State | Published - Mar 2005 |
Fingerprint
Keywords
- Contrast-enhanced CT
- Destruction-replenishment ultrasound
- Perfusion
- Tumor blood flow
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
- Radiological and Ultrasound Technology
Cite this
Contrast-enhanced computed tomography and ultrasound for the evaluation of tumor blood flow. / Broumas, Amy R.; Pollard, Rachel E; Bloch, Susannah H.; Wisner, Erik R; Griffey, Stephen M; Ferrara, Katherine W.
In: Investigative Radiology, Vol. 40, No. 3, 03.2005, p. 134-147.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Contrast-enhanced computed tomography and ultrasound for the evaluation of tumor blood flow
AU - Broumas, Amy R.
AU - Pollard, Rachel E
AU - Bloch, Susannah H.
AU - Wisner, Erik R
AU - Griffey, Stephen M
AU - Ferrara, Katherine W.
PY - 2005/3
Y1 - 2005/3
N2 - Objective: We evaluated implanted rat mammary adenocarcinoma tumors during a 5-week period using ultrasound, computed tomography (CT), and histology. Materials and Methods: Contrast-enhanced ultrasound with a destruction- replenishment imaging scheme was used to derive estimates of blood volume and flow. These ultrasound-derived measures of microvascular physiology were compared with contrast-enhanced CT-derived measures of perfusion and vascular volume made by the Mullani-Gould formula and Patlak analysis, respectively. Results: The tumor cross-sectional area and necrotic core cross-sectional area determined by the 3 methods were correlated (r2 > 0.8, P < 0.001, n = 15). The spatial integral of perfusion estimated by CT correlated with the spatial integral of flow from ultrasound (P < 0.05). The contrast-enhanced tumor area calculated from the ultrasound analysis was highly correlated with the contrast-enhanced area estimated by CT images (r2 = 0.89, P < 0.001, n = 15). However, the fraction of the tumor area enhanced by the CT contrast agent was significantly larger than either the fraction enhanced by ultrasound contrast agent or than the viable area as estimated from histology slides. Conclusion: Destruction-replenishment ultrasound provides valuable information about the spatial distribution of blood flow and vascular volume in tumors and ultrasound analysis compares favorably with a validated contrast-enhanced CT method.
AB - Objective: We evaluated implanted rat mammary adenocarcinoma tumors during a 5-week period using ultrasound, computed tomography (CT), and histology. Materials and Methods: Contrast-enhanced ultrasound with a destruction- replenishment imaging scheme was used to derive estimates of blood volume and flow. These ultrasound-derived measures of microvascular physiology were compared with contrast-enhanced CT-derived measures of perfusion and vascular volume made by the Mullani-Gould formula and Patlak analysis, respectively. Results: The tumor cross-sectional area and necrotic core cross-sectional area determined by the 3 methods were correlated (r2 > 0.8, P < 0.001, n = 15). The spatial integral of perfusion estimated by CT correlated with the spatial integral of flow from ultrasound (P < 0.05). The contrast-enhanced tumor area calculated from the ultrasound analysis was highly correlated with the contrast-enhanced area estimated by CT images (r2 = 0.89, P < 0.001, n = 15). However, the fraction of the tumor area enhanced by the CT contrast agent was significantly larger than either the fraction enhanced by ultrasound contrast agent or than the viable area as estimated from histology slides. Conclusion: Destruction-replenishment ultrasound provides valuable information about the spatial distribution of blood flow and vascular volume in tumors and ultrasound analysis compares favorably with a validated contrast-enhanced CT method.
KW - Contrast-enhanced CT
KW - Destruction-replenishment ultrasound
KW - Perfusion
KW - Tumor blood flow
UR - http://www.scopus.com/inward/record.url?scp=14244259795&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=14244259795&partnerID=8YFLogxK
U2 - 10.1097/01.rli.0000152833.35744.7f
DO - 10.1097/01.rli.0000152833.35744.7f
M3 - Article
C2 - 15714088
AN - SCOPUS:14244259795
VL - 40
SP - 134
EP - 147
JO - Investigative Radiology
JF - Investigative Radiology
SN - 0020-9996
IS - 3
ER -