T1 - Comparison of immunoaffinity column recovery patterns of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans on columns generated with different monoclonal antibody clones and polyclonal antibodies
AU - Shelver, Weilin L.
AU - Shan, Guomin
AU - Gee, Shirley J.
AU - Stanker, Larry H.
AU - Hammock, Bruce D.
PY - 2002/4/22
Y1 - 2002/4/22
N2 - Evaluation of immunoaffinity columns (IACs) for dioxin serum sample clean-up requires a determination of the recovery of various dioxin congeners. We compared the IAC performance of different monoclonal and polyclonal anti-dioxin antibodies, measuring the recovery of congeners of polychlorinated dibenzo-p-dioxins (PCDDs). In addition, we measured the recovery of congeners of the structurally related polychlorinated dibenzofurans (PCDFs). The polyclonal antibody based IACs evaluated had lower recovery for highly chlorinated dioxin congeners, but were more specific toward 2,3,7,8-TCDD. The resemblance of the hapten to 2,3,7,8-TCDD appeared to play a clear role, but chlorines in the 2-, 3- and 7-positions of the hapten were essential. Recovery of 2,3,7,8-TCDD from the IAC showed some relation to the affinity for the antibody measured by either the Ka from accelerator mass spectrometry (AMS) or with 50% inhibition of color activity (IC50) determined from an ELISA analysis. The IACs prepared from four monoclonal antibodies (Mabs) derived from a common hapten showed differences in their retention patterns of PCDDs/PCDFs. Comparison of IC50 from ELISA with recovery from the IACs indicated that a minimum IC50 of 100ppb was required for satisfactory recovery from the IAC, but the correlation was poor, indicating other factors were involved. Mab DD3 showed the broadest spectrum of the Mabs and showed satisfactory recoveries of all of the dioxin congeners, except OCDD. In addition, DD3 showed good recovery toward 2,3,4,8-TCDF, 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF but has poor recovery when PCDFs have a chlorine substitution in the 1-position.
AB - Evaluation of immunoaffinity columns (IACs) for dioxin serum sample clean-up requires a determination of the recovery of various dioxin congeners. We compared the IAC performance of different monoclonal and polyclonal anti-dioxin antibodies, measuring the recovery of congeners of polychlorinated dibenzo-p-dioxins (PCDDs). In addition, we measured the recovery of congeners of the structurally related polychlorinated dibenzofurans (PCDFs). The polyclonal antibody based IACs evaluated had lower recovery for highly chlorinated dioxin congeners, but were more specific toward 2,3,7,8-TCDD. The resemblance of the hapten to 2,3,7,8-TCDD appeared to play a clear role, but chlorines in the 2-, 3- and 7-positions of the hapten were essential. Recovery of 2,3,7,8-TCDD from the IAC showed some relation to the affinity for the antibody measured by either the Ka from accelerator mass spectrometry (AMS) or with 50% inhibition of color activity (IC50) determined from an ELISA analysis. The IACs prepared from four monoclonal antibodies (Mabs) derived from a common hapten showed differences in their retention patterns of PCDDs/PCDFs. Comparison of IC50 from ELISA with recovery from the IACs indicated that a minimum IC50 of 100ppb was required for satisfactory recovery from the IAC, but the correlation was poor, indicating other factors were involved. Mab DD3 showed the broadest spectrum of the Mabs and showed satisfactory recoveries of all of the dioxin congeners, except OCDD. In addition, DD3 showed good recovery toward 2,3,4,8-TCDF, 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF but has poor recovery when PCDFs have a chlorine substitution in the 1-position.
KW - Dioxins
KW - Furans
KW - IAC
KW - Isolation
KW - Residues
UR - http://www.scopus.com/inward/record.url?scp=0037156266&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0037156266&partnerID=8YFLogxK
U2 - 10.1016/S0003-2670(02)00019-3
DO - 10.1016/S0003-2670(02)00019-3
M3 - Article
AN - SCOPUS:0037156266
VL - 457
SP - 199
EP - 209
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
SN - 0003-2670
IS - 2
ER -