TY - JOUR
T1 - Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats
T2 - A Pilot Study
AU - Grigg, Emma K.
AU - Ueda, Yu
AU - Walker, Ashley L.
AU - Hart, Lynette A.
AU - Simas, Samany
AU - Stern, Joshua A.
N1 - Funding Information:
This work was funded by the Winn Feline Foundation, Grant Number W19-012, and the UC Davis Center for Companion Animal Health, Grant Number V451WF4. The UC Davis Library provides partial funds to support open access publication fees.
Publisher Copyright:
© Copyright © 2021 Grigg, Ueda, Walker, Hart, Simas and Stern.
PY - 2021/11/8
Y1 - 2021/11/8
N2 - Chronic exposure to stressful environments can negatively impact cats' health and welfare, affecting behavioral, autonomic, endocrine, and immune function, as with cats in shelters. Low-stress handling practices likely improve shelter cat welfare, but data supporting improved outcomes remain limited. Cardiac activity, particularly heart rate variability (HRV), is an indicator of stress and emotional state in humans and non-human animals, tracking important body functions associated with stress responsiveness, environmental adaptability, mental, and physical health. HRV studies in cats are limited, involving mainly anesthetized or restrained cats. This pilot study tested the feasibility of obtaining HRV data from unrestrained cats, using a commercially available cardiac monitoring system (Polar H10 with chest strap), compared with data from a traditional ambulatory electrocardiogram. Simultaneous data for the two systems were obtained for five adult cats. Overall, the Polar H10 monitor assessments of HRV were lower than the true HRV assessment by ambulatory ECG, except for SDNN. Correlation between the two systems was weak. Possible reasons for the lack of agreement between the two methods are discussed. At this time, our results do not support the use of Polar H10 heart rate monitors for studies of HRV in cats.
AB - Chronic exposure to stressful environments can negatively impact cats' health and welfare, affecting behavioral, autonomic, endocrine, and immune function, as with cats in shelters. Low-stress handling practices likely improve shelter cat welfare, but data supporting improved outcomes remain limited. Cardiac activity, particularly heart rate variability (HRV), is an indicator of stress and emotional state in humans and non-human animals, tracking important body functions associated with stress responsiveness, environmental adaptability, mental, and physical health. HRV studies in cats are limited, involving mainly anesthetized or restrained cats. This pilot study tested the feasibility of obtaining HRV data from unrestrained cats, using a commercially available cardiac monitoring system (Polar H10 with chest strap), compared with data from a traditional ambulatory electrocardiogram. Simultaneous data for the two systems were obtained for five adult cats. Overall, the Polar H10 monitor assessments of HRV were lower than the true HRV assessment by ambulatory ECG, except for SDNN. Correlation between the two systems was weak. Possible reasons for the lack of agreement between the two methods are discussed. At this time, our results do not support the use of Polar H10 heart rate monitors for studies of HRV in cats.
KW - cat
KW - heart rate
KW - heart rate variability
KW - Holter monitor
KW - physiological stress measures
KW - Polar H10
UR - http://www.scopus.com/inward/record.url?scp=85119686473&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85119686473&partnerID=8YFLogxK
U2 - 10.3389/fvets.2021.741583
DO - 10.3389/fvets.2021.741583
M3 - Article
AN - SCOPUS:85119686473
VL - 8
JO - Frontiers in Veterinary Science
JF - Frontiers in Veterinary Science
SN - 2297-1769
M1 - 741583
ER -