Closed Removal of a Segmental Intramedullary Rod: A Technical Report

R Randall, R. J. Hall, Peter B. Slabaugh

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

This report describes a technique for removal of a segmental broken intramedullary femoral rod. Using a closed, stacked wire technique, removal of the broken hardware can be accomplished in a relatively easy and expeditious manner.

Original languageEnglish (US)
Pages (from-to)363-365
Number of pages3
JournalJournal of Orthopaedic Trauma
Volume10
Issue number5
StatePublished - Dec 1 1996

Fingerprint

Thigh

Keywords

  • Broken hardware
  • Femoral nonunion
  • Intramedullary rod

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

Closed Removal of a Segmental Intramedullary Rod : A Technical Report. / Randall, R; Hall, R. J.; Slabaugh, Peter B.

In: Journal of Orthopaedic Trauma, Vol. 10, No. 5, 01.12.1996, p. 363-365.

Research output: Contribution to journalArticle

Randall, R ; Hall, R. J. ; Slabaugh, Peter B. / Closed Removal of a Segmental Intramedullary Rod : A Technical Report. In: Journal of Orthopaedic Trauma. 1996 ; Vol. 10, No. 5. pp. 363-365.
@article{509c87d389064fcca635b7b4c8e6db7d,
title = "Closed Removal of a Segmental Intramedullary Rod: A Technical Report",
abstract = "This report describes a technique for removal of a segmental broken intramedullary femoral rod. Using a closed, stacked wire technique, removal of the broken hardware can be accomplished in a relatively easy and expeditious manner.",
keywords = "Broken hardware, Femoral nonunion, Intramedullary rod",
author = "R Randall and Hall, {R. J.} and Slabaugh, {Peter B.}",
year = "1996",
month = "12",
day = "1",
language = "English (US)",
volume = "10",
pages = "363--365",
journal = "Journal of Orthopaedic Trauma",
issn = "0890-5339",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

TY - JOUR

T1 - Closed Removal of a Segmental Intramedullary Rod

T2 - A Technical Report

AU - Randall, R

AU - Hall, R. J.

AU - Slabaugh, Peter B.

PY - 1996/12/1

Y1 - 1996/12/1

N2 - This report describes a technique for removal of a segmental broken intramedullary femoral rod. Using a closed, stacked wire technique, removal of the broken hardware can be accomplished in a relatively easy and expeditious manner.

AB - This report describes a technique for removal of a segmental broken intramedullary femoral rod. Using a closed, stacked wire technique, removal of the broken hardware can be accomplished in a relatively easy and expeditious manner.

KW - Broken hardware

KW - Femoral nonunion

KW - Intramedullary rod

UR - http://www.scopus.com/inward/record.url?scp=0029679807&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029679807&partnerID=8YFLogxK

M3 - Article

C2 - 8814581

AN - SCOPUS:0029679807

VL - 10

SP - 363

EP - 365

JO - Journal of Orthopaedic Trauma

JF - Journal of Orthopaedic Trauma

SN - 0890-5339

IS - 5