Cardiac output determination during intravenous cardioangiography using x-ray fluorescence analysis

M. Boijsen, F. Goss, L. Jacobsson, C. Lamm, D. Schlossman, L. Björneld, Ulf Tylen

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Cardiac output was determined with an indicator dilution technique during digital venous angiography of the left ventricle in 11 patients. the contrast medium injected into the right atrium was used as indicator. During and after the injection of contrast medium one blood sample per second was obtained through a catheter placed in the descending aorta. the samples were analyzed for iodine content with x-ray fluorescence analysis and cardiac output determined ad modum Stewart-Hamilton. Thermodilution was used as a reference method. the results indicate that the indicator dilution method with the use of contrast medium might be used for calibration of videodensitometric methods for blood flow measurements

Original languageEnglish (US)
Pages (from-to)419-422
Number of pages4
JournalActa Radiologica
Volume29
Issue number4
DOIs
StatePublished - 1988
Externally publishedYes

Fingerprint

Cardiac Output
Contrast Media
Fluorescence
X-Rays
Indicator Dilution Techniques
Thermodilution
Heart Atria
Thoracic Aorta
Iodine
Calibration
Heart Ventricles
Angiography
Catheters
Injections

Keywords

  • Cardioangiography, blood flow measurement
  • X-ray fluorescence analysis

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Cardiac output determination during intravenous cardioangiography using x-ray fluorescence analysis. / Boijsen, M.; Goss, F.; Jacobsson, L.; Lamm, C.; Schlossman, D.; Björneld, L.; Tylen, Ulf.

In: Acta Radiologica, Vol. 29, No. 4, 1988, p. 419-422.

Research output: Contribution to journalArticle

Boijsen, M, Goss, F, Jacobsson, L, Lamm, C, Schlossman, D, Björneld, L & Tylen, U 1988, 'Cardiac output determination during intravenous cardioangiography using x-ray fluorescence analysis', Acta Radiologica, vol. 29, no. 4, pp. 419-422. https://doi.org/10.3109/02841858809175012
Boijsen, M. ; Goss, F. ; Jacobsson, L. ; Lamm, C. ; Schlossman, D. ; Björneld, L. ; Tylen, Ulf. / Cardiac output determination during intravenous cardioangiography using x-ray fluorescence analysis. In: Acta Radiologica. 1988 ; Vol. 29, No. 4. pp. 419-422.
@article{4c91a07b02484cef9da11358c6c33ee0,
title = "Cardiac output determination during intravenous cardioangiography using x-ray fluorescence analysis",
abstract = "Cardiac output was determined with an indicator dilution technique during digital venous angiography of the left ventricle in 11 patients. the contrast medium injected into the right atrium was used as indicator. During and after the injection of contrast medium one blood sample per second was obtained through a catheter placed in the descending aorta. the samples were analyzed for iodine content with x-ray fluorescence analysis and cardiac output determined ad modum Stewart-Hamilton. Thermodilution was used as a reference method. the results indicate that the indicator dilution method with the use of contrast medium might be used for calibration of videodensitometric methods for blood flow measurements",
keywords = "Cardioangiography, blood flow measurement, X-ray fluorescence analysis",
author = "M. Boijsen and F. Goss and L. Jacobsson and C. Lamm and D. Schlossman and L. Bj{\"o}rneld and Ulf Tylen",
year = "1988",
doi = "10.3109/02841858809175012",
language = "English (US)",
volume = "29",
pages = "419--422",
journal = "Acta Radiologica",
issn = "0284-1851",
publisher = "SAGE Publications Ltd",
number = "4",

}

TY - JOUR

T1 - Cardiac output determination during intravenous cardioangiography using x-ray fluorescence analysis

AU - Boijsen, M.

AU - Goss, F.

AU - Jacobsson, L.

AU - Lamm, C.

AU - Schlossman, D.

AU - Björneld, L.

AU - Tylen, Ulf

PY - 1988

Y1 - 1988

N2 - Cardiac output was determined with an indicator dilution technique during digital venous angiography of the left ventricle in 11 patients. the contrast medium injected into the right atrium was used as indicator. During and after the injection of contrast medium one blood sample per second was obtained through a catheter placed in the descending aorta. the samples were analyzed for iodine content with x-ray fluorescence analysis and cardiac output determined ad modum Stewart-Hamilton. Thermodilution was used as a reference method. the results indicate that the indicator dilution method with the use of contrast medium might be used for calibration of videodensitometric methods for blood flow measurements

AB - Cardiac output was determined with an indicator dilution technique during digital venous angiography of the left ventricle in 11 patients. the contrast medium injected into the right atrium was used as indicator. During and after the injection of contrast medium one blood sample per second was obtained through a catheter placed in the descending aorta. the samples were analyzed for iodine content with x-ray fluorescence analysis and cardiac output determined ad modum Stewart-Hamilton. Thermodilution was used as a reference method. the results indicate that the indicator dilution method with the use of contrast medium might be used for calibration of videodensitometric methods for blood flow measurements

KW - Cardioangiography, blood flow measurement

KW - X-ray fluorescence analysis

UR - http://www.scopus.com/inward/record.url?scp=0023677370&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023677370&partnerID=8YFLogxK

U2 - 10.3109/02841858809175012

DO - 10.3109/02841858809175012

M3 - Article

C2 - 3408602

AN - SCOPUS:0023677370

VL - 29

SP - 419

EP - 422

JO - Acta Radiologica

JF - Acta Radiologica

SN - 0284-1851

IS - 4

ER -