TY - JOUR
T1 - Biomechanical evaluation of two plating configurations for fixation of a simple transverse caudal mandibular fracture model in cats
AU - Greiner, Christopher L.
AU - Verstraete, Frank J
AU - Stover, Susan M
AU - Garcia, Tanya C.
AU - Leale, Dustin
AU - Arzi, Boaz
PY - 2017
Y1 - 2017
N2 - OBJECTIVE To evaluate biomechanical properties of intact feline mandibles, compared with those for mandibles with an experimentally created osteotomy that was stabilized with 1 of 2 internal fixation configurations. SAMPLE 20 mandibles from 10 adult feline cadavers. PROCEDURES An incomplete block study design was used to assign the mandibles of each cadaver to 2 of 3 groups (locking plate with locking screws [locking con-struct], locking plate with nonlocking screws [nonlocking construct], or intact). Within each cadaver, mandibles were randomly assigned to the assigned treatments. For mandibles assigned to the locking and nonlocking constructs, a simple transverse osteotomy was created caudal to the mandibular first molar tooth after plate application. All mandibles were loaded in cantilever bending in a single-load-to-failure test while simultaneously recording load and actuator displacement. Mode of failure (bone or plate failure) was recorded, and radiographic evidence of tooth root and mandibular canal damage was evaluated. Mechanical properties were compared among the 3 groups. RESULTS Stiffness, bending moments, and most post-yield energies for mandibles with the locking and nonlocking constructs were significantly lower than those for intact mandibles. Peak bending moment and stiffness for mandibles with the locking construct were significantly greater than those for mandibles with the nonlocking construct. Mode of failure and frequency of screw damage to tooth roots and the mandibular canal did not differ between the locking and nonlocking constructs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that both fixation constructs were mechanically inferior to intact mandibles. The locking construct was mechanically stronger than the nonlocking construct.
AB - OBJECTIVE To evaluate biomechanical properties of intact feline mandibles, compared with those for mandibles with an experimentally created osteotomy that was stabilized with 1 of 2 internal fixation configurations. SAMPLE 20 mandibles from 10 adult feline cadavers. PROCEDURES An incomplete block study design was used to assign the mandibles of each cadaver to 2 of 3 groups (locking plate with locking screws [locking con-struct], locking plate with nonlocking screws [nonlocking construct], or intact). Within each cadaver, mandibles were randomly assigned to the assigned treatments. For mandibles assigned to the locking and nonlocking constructs, a simple transverse osteotomy was created caudal to the mandibular first molar tooth after plate application. All mandibles were loaded in cantilever bending in a single-load-to-failure test while simultaneously recording load and actuator displacement. Mode of failure (bone or plate failure) was recorded, and radiographic evidence of tooth root and mandibular canal damage was evaluated. Mechanical properties were compared among the 3 groups. RESULTS Stiffness, bending moments, and most post-yield energies for mandibles with the locking and nonlocking constructs were significantly lower than those for intact mandibles. Peak bending moment and stiffness for mandibles with the locking construct were significantly greater than those for mandibles with the nonlocking construct. Mode of failure and frequency of screw damage to tooth roots and the mandibular canal did not differ between the locking and nonlocking constructs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that both fixation constructs were mechanically inferior to intact mandibles. The locking construct was mechanically stronger than the nonlocking construct.
UR - http://www.scopus.com/inward/record.url?scp=85019733986&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85019733986&partnerID=8YFLogxK
U2 - 10.2460/ajvr.78.6.702
DO - 10.2460/ajvr.78.6.702
M3 - Article
C2 - 28541156
AN - SCOPUS:85019733986
VL - 78
SP - 702
EP - 711
JO - American Journal of Veterinary Research
JF - American Journal of Veterinary Research
SN - 0002-9645
IS - 6
ER -