Nutzen patientenbezogener kontrastmittelprotokolle fur die kardiovaskulare computertomographie

Translated title of the contribution: Benefits of patient-oriented contrast medium injection protocols for cardiovascular computed tomography

Friedrich D Knollmann, R. Hetzer, R. Felix

Research output: Contribution to journalArticle

Abstract

Purpose: To determine the temporal variability of the time to maximum aortic density after peripheral venous contrast injection in cardiovascular CT studies and to calculate potential contrast agent savings of selecting scan delay from test bolus kinetics. Methods: A peripheral contrast bolus was administered intravenously in 138 consecutive patients to determine the time to maximum density in a left ventricular or aortic region of interest by electron beam CT. 20 EKG-triggered scans were acquired within 70 heartbeats. The deviation of the time to maximum density from a standard, fixed scan delay was determined. Results: Mean time to maximum density was 22 s, and the average deviation from that mean was 5 s. At an injection rate of 4 cc/s, this deviation implies that determining the individual scan delay from a test bolus injection may potentially save 20 cc contrast per patient. This amount of contrast agent, in turn, is required for the test bolus. Conclusion: Deriving the individual scan delay from test bolus kinetics may improve image contrast in cardiovascular CT studies without additional contrast expense.

Original languageGerman
Pages (from-to)335-339
Number of pages5
JournalRontgenpraxis
Volume52
Issue number10-12
StatePublished - 2000
Externally publishedYes

Fingerprint

Contrast Media
Tomography
Injections
Electrocardiography
Electrons

Keywords

  • Aorta-heart
  • Computed tomography
  • Contrast media
  • Electron beam tomography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Nutzen patientenbezogener kontrastmittelprotokolle fur die kardiovaskulare computertomographie. / Knollmann, Friedrich D; Hetzer, R.; Felix, R.

In: Rontgenpraxis, Vol. 52, No. 10-12, 2000, p. 335-339.

Research output: Contribution to journalArticle

@article{3864e2c31eb842b9a99e4486cbbb0198,
title = "Nutzen patientenbezogener kontrastmittelprotokolle fur die kardiovaskulare computertomographie",
abstract = "Purpose: To determine the temporal variability of the time to maximum aortic density after peripheral venous contrast injection in cardiovascular CT studies and to calculate potential contrast agent savings of selecting scan delay from test bolus kinetics. Methods: A peripheral contrast bolus was administered intravenously in 138 consecutive patients to determine the time to maximum density in a left ventricular or aortic region of interest by electron beam CT. 20 EKG-triggered scans were acquired within 70 heartbeats. The deviation of the time to maximum density from a standard, fixed scan delay was determined. Results: Mean time to maximum density was 22 s, and the average deviation from that mean was 5 s. At an injection rate of 4 cc/s, this deviation implies that determining the individual scan delay from a test bolus injection may potentially save 20 cc contrast per patient. This amount of contrast agent, in turn, is required for the test bolus. Conclusion: Deriving the individual scan delay from test bolus kinetics may improve image contrast in cardiovascular CT studies without additional contrast expense.",
keywords = "Aorta-heart, Computed tomography, Contrast media, Electron beam tomography",
author = "Knollmann, {Friedrich D} and R. Hetzer and R. Felix",
year = "2000",
language = "German",
volume = "52",
pages = "335--339",
journal = "Rontgenpraxis; Zeitschrift fur radiologische Technik",
issn = "0035-7820",
publisher = "Elsevier BV",
number = "10-12",

}

TY - JOUR

T1 - Nutzen patientenbezogener kontrastmittelprotokolle fur die kardiovaskulare computertomographie

AU - Knollmann, Friedrich D

AU - Hetzer, R.

AU - Felix, R.

PY - 2000

Y1 - 2000

N2 - Purpose: To determine the temporal variability of the time to maximum aortic density after peripheral venous contrast injection in cardiovascular CT studies and to calculate potential contrast agent savings of selecting scan delay from test bolus kinetics. Methods: A peripheral contrast bolus was administered intravenously in 138 consecutive patients to determine the time to maximum density in a left ventricular or aortic region of interest by electron beam CT. 20 EKG-triggered scans were acquired within 70 heartbeats. The deviation of the time to maximum density from a standard, fixed scan delay was determined. Results: Mean time to maximum density was 22 s, and the average deviation from that mean was 5 s. At an injection rate of 4 cc/s, this deviation implies that determining the individual scan delay from a test bolus injection may potentially save 20 cc contrast per patient. This amount of contrast agent, in turn, is required for the test bolus. Conclusion: Deriving the individual scan delay from test bolus kinetics may improve image contrast in cardiovascular CT studies without additional contrast expense.

AB - Purpose: To determine the temporal variability of the time to maximum aortic density after peripheral venous contrast injection in cardiovascular CT studies and to calculate potential contrast agent savings of selecting scan delay from test bolus kinetics. Methods: A peripheral contrast bolus was administered intravenously in 138 consecutive patients to determine the time to maximum density in a left ventricular or aortic region of interest by electron beam CT. 20 EKG-triggered scans were acquired within 70 heartbeats. The deviation of the time to maximum density from a standard, fixed scan delay was determined. Results: Mean time to maximum density was 22 s, and the average deviation from that mean was 5 s. At an injection rate of 4 cc/s, this deviation implies that determining the individual scan delay from a test bolus injection may potentially save 20 cc contrast per patient. This amount of contrast agent, in turn, is required for the test bolus. Conclusion: Deriving the individual scan delay from test bolus kinetics may improve image contrast in cardiovascular CT studies without additional contrast expense.

KW - Aorta-heart

KW - Computed tomography

KW - Contrast media

KW - Electron beam tomography

UR - http://www.scopus.com/inward/record.url?scp=0034013916&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034013916&partnerID=8YFLogxK

M3 - Article

C2 - 10803045

AN - SCOPUS:0034013916

VL - 52

SP - 335

EP - 339

JO - Rontgenpraxis; Zeitschrift fur radiologische Technik

JF - Rontgenpraxis; Zeitschrift fur radiologische Technik

SN - 0035-7820

IS - 10-12

ER -