Analysis of trace elements in animal tissues - III. Determination of managanese by graphite furnace atomic absorption spectrophotometry

Michael S. Clegg, Carl L Keen, Bo Lonnerdal, Lucille S. Hurley

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Graphite furnace atomic absorption spectrophotometry is a method used for the measurement of low concentrations of manganese (ppb range). Despite the widespread use of this technique, there is considerable inconsistency concerning sample preparation and choice of instrumental parameters. In this paper, we determined manganese concentrations of National Bureau of Standards (NBS) bovine liver by both graphite furnace (Instrumentation Laboratory IL 555B) and flame atomic absorption following wet digestion of the sample with nitric acid. The following instrumental parameters for the graphite furnace were found optimal for the measurement of manganese in digested NBS bovine liver: inert gas flow=14 SCFH, drying temperature 100°C/15 s (step 1), 125°C/15 s (step 2), pyrolysis temperature 500°C/15 s (step 3), and 1000°C/15 s (step 4); atomization temperature 2250°C/10 s (step 5). For optimal results, the nitric acid concentration of the sample should be between 2 and 4 M. There were no significant differences found for manganese concentrations determined by either peak height or peak area measurement. Additionally, no significant differences were found in manganese concentrations determined by flame or furnace methods. Assuming proper sample preparation and choice of instrumental parameters, values obtained for manganese concentration by graphite furnace and flame atomic absorption spectrophotometry are similar. Therefore, data obtained by these two methods can be compared directly.

Original languageEnglish (US)
Pages (from-to)145-156
Number of pages12
JournalBiological Trace Element Research
Volume4
Issue number2-3
DOIs
StatePublished - Jun 1982

Fingerprint

Atomic Spectrophotometry
Graphite
Spectrophotometry
Trace Elements
Manganese
Animals
Furnaces
Tissue
Nitric Acid
Liver
Temperature
Noble Gases
Atomization
Flow of gases
Digestion
Drying
Pyrolysis

Keywords

  • analysis of biological trace elements
  • atomic absorption spectrophotometry, of Mn in animal tissues
  • biological samples
  • biotrace element analysis, of Mn
  • instrumental parameters, in biological trace element analysis
  • Manganese determination, by graphite furnace AAS
  • methods in biological trace element analysis

ASJC Scopus subject areas

  • Endocrinology, Diabetes and Metabolism
  • Endocrinology
  • Biochemistry, Genetics and Molecular Biology(all)

Cite this

Analysis of trace elements in animal tissues - III. Determination of managanese by graphite furnace atomic absorption spectrophotometry. / Clegg, Michael S.; Keen, Carl L; Lonnerdal, Bo; Hurley, Lucille S.

In: Biological Trace Element Research, Vol. 4, No. 2-3, 06.1982, p. 145-156.

Research output: Contribution to journalArticle

Clegg, Michael S. ; Keen, Carl L ; Lonnerdal, Bo ; Hurley, Lucille S. / Analysis of trace elements in animal tissues - III. Determination of managanese by graphite furnace atomic absorption spectrophotometry. In: Biological Trace Element Research. 1982 ; Vol. 4, No. 2-3. pp. 145-156.
@article{dfe10d12977449d78e57d7a27f17b059,
title = "Analysis of trace elements in animal tissues - III. Determination of managanese by graphite furnace atomic absorption spectrophotometry",
abstract = "Graphite furnace atomic absorption spectrophotometry is a method used for the measurement of low concentrations of manganese (ppb range). Despite the widespread use of this technique, there is considerable inconsistency concerning sample preparation and choice of instrumental parameters. In this paper, we determined manganese concentrations of National Bureau of Standards (NBS) bovine liver by both graphite furnace (Instrumentation Laboratory IL 555B) and flame atomic absorption following wet digestion of the sample with nitric acid. The following instrumental parameters for the graphite furnace were found optimal for the measurement of manganese in digested NBS bovine liver: inert gas flow=14 SCFH, drying temperature 100°C/15 s (step 1), 125°C/15 s (step 2), pyrolysis temperature 500°C/15 s (step 3), and 1000°C/15 s (step 4); atomization temperature 2250°C/10 s (step 5). For optimal results, the nitric acid concentration of the sample should be between 2 and 4 M. There were no significant differences found for manganese concentrations determined by either peak height or peak area measurement. Additionally, no significant differences were found in manganese concentrations determined by flame or furnace methods. Assuming proper sample preparation and choice of instrumental parameters, values obtained for manganese concentration by graphite furnace and flame atomic absorption spectrophotometry are similar. Therefore, data obtained by these two methods can be compared directly.",
keywords = "analysis of biological trace elements, atomic absorption spectrophotometry, of Mn in animal tissues, biological samples, biotrace element analysis, of Mn, instrumental parameters, in biological trace element analysis, Manganese determination, by graphite furnace AAS, methods in biological trace element analysis",
author = "Clegg, {Michael S.} and Keen, {Carl L} and Bo Lonnerdal and Hurley, {Lucille S.}",
year = "1982",
month = "6",
doi = "10.1007/BF02783254",
language = "English (US)",
volume = "4",
pages = "145--156",
journal = "Biological Trace Element Research",
issn = "0163-4984",
publisher = "Humana Press",
number = "2-3",

}

TY - JOUR

T1 - Analysis of trace elements in animal tissues - III. Determination of managanese by graphite furnace atomic absorption spectrophotometry

AU - Clegg, Michael S.

AU - Keen, Carl L

AU - Lonnerdal, Bo

AU - Hurley, Lucille S.

PY - 1982/6

Y1 - 1982/6

N2 - Graphite furnace atomic absorption spectrophotometry is a method used for the measurement of low concentrations of manganese (ppb range). Despite the widespread use of this technique, there is considerable inconsistency concerning sample preparation and choice of instrumental parameters. In this paper, we determined manganese concentrations of National Bureau of Standards (NBS) bovine liver by both graphite furnace (Instrumentation Laboratory IL 555B) and flame atomic absorption following wet digestion of the sample with nitric acid. The following instrumental parameters for the graphite furnace were found optimal for the measurement of manganese in digested NBS bovine liver: inert gas flow=14 SCFH, drying temperature 100°C/15 s (step 1), 125°C/15 s (step 2), pyrolysis temperature 500°C/15 s (step 3), and 1000°C/15 s (step 4); atomization temperature 2250°C/10 s (step 5). For optimal results, the nitric acid concentration of the sample should be between 2 and 4 M. There were no significant differences found for manganese concentrations determined by either peak height or peak area measurement. Additionally, no significant differences were found in manganese concentrations determined by flame or furnace methods. Assuming proper sample preparation and choice of instrumental parameters, values obtained for manganese concentration by graphite furnace and flame atomic absorption spectrophotometry are similar. Therefore, data obtained by these two methods can be compared directly.

AB - Graphite furnace atomic absorption spectrophotometry is a method used for the measurement of low concentrations of manganese (ppb range). Despite the widespread use of this technique, there is considerable inconsistency concerning sample preparation and choice of instrumental parameters. In this paper, we determined manganese concentrations of National Bureau of Standards (NBS) bovine liver by both graphite furnace (Instrumentation Laboratory IL 555B) and flame atomic absorption following wet digestion of the sample with nitric acid. The following instrumental parameters for the graphite furnace were found optimal for the measurement of manganese in digested NBS bovine liver: inert gas flow=14 SCFH, drying temperature 100°C/15 s (step 1), 125°C/15 s (step 2), pyrolysis temperature 500°C/15 s (step 3), and 1000°C/15 s (step 4); atomization temperature 2250°C/10 s (step 5). For optimal results, the nitric acid concentration of the sample should be between 2 and 4 M. There were no significant differences found for manganese concentrations determined by either peak height or peak area measurement. Additionally, no significant differences were found in manganese concentrations determined by flame or furnace methods. Assuming proper sample preparation and choice of instrumental parameters, values obtained for manganese concentration by graphite furnace and flame atomic absorption spectrophotometry are similar. Therefore, data obtained by these two methods can be compared directly.

KW - analysis of biological trace elements

KW - atomic absorption spectrophotometry, of Mn in animal tissues

KW - biological samples

KW - biotrace element analysis, of Mn

KW - instrumental parameters, in biological trace element analysis

KW - Manganese determination, by graphite furnace AAS

KW - methods in biological trace element analysis

UR - http://www.scopus.com/inward/record.url?scp=0020449463&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020449463&partnerID=8YFLogxK

U2 - 10.1007/BF02783254

DO - 10.1007/BF02783254

M3 - Article

AN - SCOPUS:0020449463

VL - 4

SP - 145

EP - 156

JO - Biological Trace Element Research

JF - Biological Trace Element Research

SN - 0163-4984

IS - 2-3

ER -