An on-chip microfluidic pressure regulator that facilitates reproducible loading of cells and hydrogels into microphysiological system platforms

Xiaolin Wang, Duc T.T. Phan, Da Zhao, Steven George, Christopher C.W. Hughes, Abraham P. Lee

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Coculturing multiple cell types together in 3-dimensional (3D) cultures better mimics the in vivo microphysiological environment, and has become widely adopted in recent years with the development of organ-on-chip systems. However, a bottleneck in set-up of these devices arises as a result of the delivery of the gel into the microfluidic chip being sensitive to pressure fluctuations, making gel confinement at a specific region challenging, especially when manual operation is performed. In this paper, we present a novel design of an on-chip regulator module with pressure-releasing safety microvalves that can facilitate stable gel delivery into designated microchannel regions while maintaining well-controlled, non-bursting gel interfaces. This pressure regulator design can be integrated into different microfluidic chip designs and is compatible with a wide variety of gel injection apparatuses operated automatically or manually at different flow rates. The sensitivity and working range of this pressure regulator can be adjusted by changing the width of its pressure releasing safety microvalve design. The effectiveness of the design is validated by its incorporation into a microfluidic platform we have developed for generating 3D vascularized micro-organs (VMOs). Reproducible gel loading is demonstrated for both an automatic syringe pump and a manually-operated micropipettor. This design allows for rapid and reproducible loading of hydrogels into microfluidic devices without the risk of bursting gel-air interfaces.

Original languageEnglish (US)
Pages (from-to)868-876
Number of pages9
JournalLab on a Chip
Volume16
Issue number5
DOIs
StatePublished - Jan 1 2016
Externally publishedYes

Fingerprint

Pressure regulators
Hydrogels
Microfluidics
Gels
Pressure
Lab-On-A-Chip Devices
Safety
Syringes
Microchannels
Air
Flow rate
Pumps
Equipment and Supplies
Injections

ASJC Scopus subject areas

  • Bioengineering
  • Biochemistry
  • Chemistry(all)
  • Biomedical Engineering

Cite this

An on-chip microfluidic pressure regulator that facilitates reproducible loading of cells and hydrogels into microphysiological system platforms. / Wang, Xiaolin; Phan, Duc T.T.; Zhao, Da; George, Steven; Hughes, Christopher C.W.; Lee, Abraham P.

In: Lab on a Chip, Vol. 16, No. 5, 01.01.2016, p. 868-876.

Research output: Contribution to journalArticle

Wang, Xiaolin ; Phan, Duc T.T. ; Zhao, Da ; George, Steven ; Hughes, Christopher C.W. ; Lee, Abraham P. / An on-chip microfluidic pressure regulator that facilitates reproducible loading of cells and hydrogels into microphysiological system platforms. In: Lab on a Chip. 2016 ; Vol. 16, No. 5. pp. 868-876.
@article{2c7f786e74144eb1a1434fcd9721b3dd,
title = "An on-chip microfluidic pressure regulator that facilitates reproducible loading of cells and hydrogels into microphysiological system platforms",
abstract = "Coculturing multiple cell types together in 3-dimensional (3D) cultures better mimics the in vivo microphysiological environment, and has become widely adopted in recent years with the development of organ-on-chip systems. However, a bottleneck in set-up of these devices arises as a result of the delivery of the gel into the microfluidic chip being sensitive to pressure fluctuations, making gel confinement at a specific region challenging, especially when manual operation is performed. In this paper, we present a novel design of an on-chip regulator module with pressure-releasing safety microvalves that can facilitate stable gel delivery into designated microchannel regions while maintaining well-controlled, non-bursting gel interfaces. This pressure regulator design can be integrated into different microfluidic chip designs and is compatible with a wide variety of gel injection apparatuses operated automatically or manually at different flow rates. The sensitivity and working range of this pressure regulator can be adjusted by changing the width of its pressure releasing safety microvalve design. The effectiveness of the design is validated by its incorporation into a microfluidic platform we have developed for generating 3D vascularized micro-organs (VMOs). Reproducible gel loading is demonstrated for both an automatic syringe pump and a manually-operated micropipettor. This design allows for rapid and reproducible loading of hydrogels into microfluidic devices without the risk of bursting gel-air interfaces.",
author = "Xiaolin Wang and Phan, {Duc T.T.} and Da Zhao and Steven George and Hughes, {Christopher C.W.} and Lee, {Abraham P.}",
year = "2016",
month = "1",
day = "1",
doi = "10.1039/c5lc01563d",
language = "English (US)",
volume = "16",
pages = "868--876",
journal = "Lab on a Chip - Miniaturisation for Chemistry and Biology",
issn = "1473-0197",
publisher = "Royal Society of Chemistry",
number = "5",

}

TY - JOUR

T1 - An on-chip microfluidic pressure regulator that facilitates reproducible loading of cells and hydrogels into microphysiological system platforms

AU - Wang, Xiaolin

AU - Phan, Duc T.T.

AU - Zhao, Da

AU - George, Steven

AU - Hughes, Christopher C.W.

AU - Lee, Abraham P.

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Coculturing multiple cell types together in 3-dimensional (3D) cultures better mimics the in vivo microphysiological environment, and has become widely adopted in recent years with the development of organ-on-chip systems. However, a bottleneck in set-up of these devices arises as a result of the delivery of the gel into the microfluidic chip being sensitive to pressure fluctuations, making gel confinement at a specific region challenging, especially when manual operation is performed. In this paper, we present a novel design of an on-chip regulator module with pressure-releasing safety microvalves that can facilitate stable gel delivery into designated microchannel regions while maintaining well-controlled, non-bursting gel interfaces. This pressure regulator design can be integrated into different microfluidic chip designs and is compatible with a wide variety of gel injection apparatuses operated automatically or manually at different flow rates. The sensitivity and working range of this pressure regulator can be adjusted by changing the width of its pressure releasing safety microvalve design. The effectiveness of the design is validated by its incorporation into a microfluidic platform we have developed for generating 3D vascularized micro-organs (VMOs). Reproducible gel loading is demonstrated for both an automatic syringe pump and a manually-operated micropipettor. This design allows for rapid and reproducible loading of hydrogels into microfluidic devices without the risk of bursting gel-air interfaces.

AB - Coculturing multiple cell types together in 3-dimensional (3D) cultures better mimics the in vivo microphysiological environment, and has become widely adopted in recent years with the development of organ-on-chip systems. However, a bottleneck in set-up of these devices arises as a result of the delivery of the gel into the microfluidic chip being sensitive to pressure fluctuations, making gel confinement at a specific region challenging, especially when manual operation is performed. In this paper, we present a novel design of an on-chip regulator module with pressure-releasing safety microvalves that can facilitate stable gel delivery into designated microchannel regions while maintaining well-controlled, non-bursting gel interfaces. This pressure regulator design can be integrated into different microfluidic chip designs and is compatible with a wide variety of gel injection apparatuses operated automatically or manually at different flow rates. The sensitivity and working range of this pressure regulator can be adjusted by changing the width of its pressure releasing safety microvalve design. The effectiveness of the design is validated by its incorporation into a microfluidic platform we have developed for generating 3D vascularized micro-organs (VMOs). Reproducible gel loading is demonstrated for both an automatic syringe pump and a manually-operated micropipettor. This design allows for rapid and reproducible loading of hydrogels into microfluidic devices without the risk of bursting gel-air interfaces.

UR - http://www.scopus.com/inward/record.url?scp=84975757942&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84975757942&partnerID=8YFLogxK

U2 - 10.1039/c5lc01563d

DO - 10.1039/c5lc01563d

M3 - Article

C2 - 26879519

AN - SCOPUS:84975757942

VL - 16

SP - 868

EP - 876

JO - Lab on a Chip - Miniaturisation for Chemistry and Biology

JF - Lab on a Chip - Miniaturisation for Chemistry and Biology

SN - 1473-0197

IS - 5

ER -