An insulin-dose error assessment grid: A new tool to evaluate glucose meter performance

Martha E. Lyon, Oliver A.S. Lyon, Nam Tran, Jeffrey A. DuBois, Andrew W. Lyon

Research output: Contribution to journalArticle

Abstract

Objective: To develop a tool to assess the clinical accuracy of glucose meter performance using an insulin dosing protocol to assess the frequency and extent of error in insulin dose categories. Methods: Retrospective comparison of 1815 glucose meter and central laboratory glucose results obtained from 1698 critically ill patients was conducted using the Parkes error grid, Surveillance error grid and an insulin dose error assessment grid with a sliding scale insulin dosing protocol used to manage critically ill patients. Results: Parkes error grid and Surveillance error grid analyses indicated little risk conferred with the glucose meter results. Insulin dose error assessment grid complemented the aforementioned consensus error grids by determining quantifiable metrics, insulin dose category errors. Insulin dose error analysis indicated that 76.8% (1395/1815) would not have any change in insulin dose, 99.2% (1800/1815) within ±1 insulin dose category, 99.9% (1814/1815) within ±2 categories and 100% within ±3 insulin dose categories. Conclusions: Analysis with an insulin dose error grid provides information about the frequency and extent of insulin dose category errors with a specific insulin dosing protocol and describes potential clinical impact of glucose meter error.

Original languageEnglish (US)
Pages (from-to)30-33
Number of pages4
JournalClinical Biochemistry
Volume70
DOIs
StatePublished - Aug 1 2019

Fingerprint

Insulin
Glucose
Critical Illness
Error analysis

Keywords

  • Analytic error
  • Diabetes
  • Glycemic control
  • Parkes error grid
  • Quality assurance
  • Surveillance error grid

ASJC Scopus subject areas

  • Clinical Biochemistry

Cite this

An insulin-dose error assessment grid : A new tool to evaluate glucose meter performance. / Lyon, Martha E.; Lyon, Oliver A.S.; Tran, Nam; DuBois, Jeffrey A.; Lyon, Andrew W.

In: Clinical Biochemistry, Vol. 70, 01.08.2019, p. 30-33.

Research output: Contribution to journalArticle

Lyon, Martha E. ; Lyon, Oliver A.S. ; Tran, Nam ; DuBois, Jeffrey A. ; Lyon, Andrew W. / An insulin-dose error assessment grid : A new tool to evaluate glucose meter performance. In: Clinical Biochemistry. 2019 ; Vol. 70. pp. 30-33.
@article{e3f22e4c2ee84af0ba16ac66cf4e2951,
title = "An insulin-dose error assessment grid: A new tool to evaluate glucose meter performance",
abstract = "Objective: To develop a tool to assess the clinical accuracy of glucose meter performance using an insulin dosing protocol to assess the frequency and extent of error in insulin dose categories. Methods: Retrospective comparison of 1815 glucose meter and central laboratory glucose results obtained from 1698 critically ill patients was conducted using the Parkes error grid, Surveillance error grid and an insulin dose error assessment grid with a sliding scale insulin dosing protocol used to manage critically ill patients. Results: Parkes error grid and Surveillance error grid analyses indicated little risk conferred with the glucose meter results. Insulin dose error assessment grid complemented the aforementioned consensus error grids by determining quantifiable metrics, insulin dose category errors. Insulin dose error analysis indicated that 76.8{\%} (1395/1815) would not have any change in insulin dose, 99.2{\%} (1800/1815) within ±1 insulin dose category, 99.9{\%} (1814/1815) within ±2 categories and 100{\%} within ±3 insulin dose categories. Conclusions: Analysis with an insulin dose error grid provides information about the frequency and extent of insulin dose category errors with a specific insulin dosing protocol and describes potential clinical impact of glucose meter error.",
keywords = "Analytic error, Diabetes, Glycemic control, Parkes error grid, Quality assurance, Surveillance error grid",
author = "Lyon, {Martha E.} and Lyon, {Oliver A.S.} and Nam Tran and DuBois, {Jeffrey A.} and Lyon, {Andrew W.}",
year = "2019",
month = "8",
day = "1",
doi = "10.1016/j.clinbiochem.2019.06.001",
language = "English (US)",
volume = "70",
pages = "30--33",
journal = "Clinical Biochemistry",
issn = "0009-9120",
publisher = "Elsevier Inc.",

}

TY - JOUR

T1 - An insulin-dose error assessment grid

T2 - A new tool to evaluate glucose meter performance

AU - Lyon, Martha E.

AU - Lyon, Oliver A.S.

AU - Tran, Nam

AU - DuBois, Jeffrey A.

AU - Lyon, Andrew W.

PY - 2019/8/1

Y1 - 2019/8/1

N2 - Objective: To develop a tool to assess the clinical accuracy of glucose meter performance using an insulin dosing protocol to assess the frequency and extent of error in insulin dose categories. Methods: Retrospective comparison of 1815 glucose meter and central laboratory glucose results obtained from 1698 critically ill patients was conducted using the Parkes error grid, Surveillance error grid and an insulin dose error assessment grid with a sliding scale insulin dosing protocol used to manage critically ill patients. Results: Parkes error grid and Surveillance error grid analyses indicated little risk conferred with the glucose meter results. Insulin dose error assessment grid complemented the aforementioned consensus error grids by determining quantifiable metrics, insulin dose category errors. Insulin dose error analysis indicated that 76.8% (1395/1815) would not have any change in insulin dose, 99.2% (1800/1815) within ±1 insulin dose category, 99.9% (1814/1815) within ±2 categories and 100% within ±3 insulin dose categories. Conclusions: Analysis with an insulin dose error grid provides information about the frequency and extent of insulin dose category errors with a specific insulin dosing protocol and describes potential clinical impact of glucose meter error.

AB - Objective: To develop a tool to assess the clinical accuracy of glucose meter performance using an insulin dosing protocol to assess the frequency and extent of error in insulin dose categories. Methods: Retrospective comparison of 1815 glucose meter and central laboratory glucose results obtained from 1698 critically ill patients was conducted using the Parkes error grid, Surveillance error grid and an insulin dose error assessment grid with a sliding scale insulin dosing protocol used to manage critically ill patients. Results: Parkes error grid and Surveillance error grid analyses indicated little risk conferred with the glucose meter results. Insulin dose error assessment grid complemented the aforementioned consensus error grids by determining quantifiable metrics, insulin dose category errors. Insulin dose error analysis indicated that 76.8% (1395/1815) would not have any change in insulin dose, 99.2% (1800/1815) within ±1 insulin dose category, 99.9% (1814/1815) within ±2 categories and 100% within ±3 insulin dose categories. Conclusions: Analysis with an insulin dose error grid provides information about the frequency and extent of insulin dose category errors with a specific insulin dosing protocol and describes potential clinical impact of glucose meter error.

KW - Analytic error

KW - Diabetes

KW - Glycemic control

KW - Parkes error grid

KW - Quality assurance

KW - Surveillance error grid

UR - http://www.scopus.com/inward/record.url?scp=85066786419&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85066786419&partnerID=8YFLogxK

U2 - 10.1016/j.clinbiochem.2019.06.001

DO - 10.1016/j.clinbiochem.2019.06.001

M3 - Article

C2 - 31170380

AN - SCOPUS:85066786419

VL - 70

SP - 30

EP - 33

JO - Clinical Biochemistry

JF - Clinical Biochemistry

SN - 0009-9120