An initial description of a sonographic sign that verifies intrathoracic chest tube placement

Toby O. Salz, Sharon R. Wilson, Otto Liebmann, Daniel D. Price

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Purpose: An initial description of a sonographic finding predictive of intrathoracic chest tube placement. Methods: This was a prospective observational study using unembalmed cadaveric models. Chest tubes were randomly placed intra- and extrathoracically and evaluated using ultrasound. Chest tube location was confirmed using blunt dissection followed by tactile and visual confirmation. Sonographers were blinded to chest tube position. Sonographic images obtained in a transverse orientation revealed a subcutaneous hyperechoic arc, created by the chest tube, at the insertion site. The path of the hyperechoic arc was followed cephalad. Disappearance of the hyperechoic arc signified intrathoracic chest tube placement. In contrast, continuation of a subcutaneous hyperechoic arc for the full length of the chest tube signified extrathoracic chest tube placement (the Disappearance/Intrathoracic, Continuation/Extrathoracic sign). Results: Ultrasound was used to evaluate 48 chest tube placements. All chest tube locations were identified correctly. In differentiating intra- vs extrathoracic chest tube placement, the Disappearance/Intrathoracic, Continuation/Extrathoracic sign revealed a sensitivity of 100% (95% confidence interval, 83%-100%) and a specificity of 100% (95% confidence interval, 83%-100%). Conclusions: In this small study, bedside ultrasound appears to be highly sensitive and specific in differentiating intra- versus extrathoracic chest tube placement.

Original languageEnglish (US)
Pages (from-to)626-630
Number of pages5
JournalAmerican Journal of Emergency Medicine
Volume28
Issue number5
DOIs
StatePublished - Jun 2010

Fingerprint

Chest Tubes
Confidence Intervals
Touch
Observational Studies
Dissection

ASJC Scopus subject areas

  • Emergency Medicine

Cite this

An initial description of a sonographic sign that verifies intrathoracic chest tube placement. / Salz, Toby O.; Wilson, Sharon R.; Liebmann, Otto; Price, Daniel D.

In: American Journal of Emergency Medicine, Vol. 28, No. 5, 06.2010, p. 626-630.

Research output: Contribution to journalArticle

Salz, Toby O. ; Wilson, Sharon R. ; Liebmann, Otto ; Price, Daniel D. / An initial description of a sonographic sign that verifies intrathoracic chest tube placement. In: American Journal of Emergency Medicine. 2010 ; Vol. 28, No. 5. pp. 626-630.
@article{26039478cac2457b9252925f6871993d,
title = "An initial description of a sonographic sign that verifies intrathoracic chest tube placement",
abstract = "Purpose: An initial description of a sonographic finding predictive of intrathoracic chest tube placement. Methods: This was a prospective observational study using unembalmed cadaveric models. Chest tubes were randomly placed intra- and extrathoracically and evaluated using ultrasound. Chest tube location was confirmed using blunt dissection followed by tactile and visual confirmation. Sonographers were blinded to chest tube position. Sonographic images obtained in a transverse orientation revealed a subcutaneous hyperechoic arc, created by the chest tube, at the insertion site. The path of the hyperechoic arc was followed cephalad. Disappearance of the hyperechoic arc signified intrathoracic chest tube placement. In contrast, continuation of a subcutaneous hyperechoic arc for the full length of the chest tube signified extrathoracic chest tube placement (the Disappearance/Intrathoracic, Continuation/Extrathoracic sign). Results: Ultrasound was used to evaluate 48 chest tube placements. All chest tube locations were identified correctly. In differentiating intra- vs extrathoracic chest tube placement, the Disappearance/Intrathoracic, Continuation/Extrathoracic sign revealed a sensitivity of 100{\%} (95{\%} confidence interval, 83{\%}-100{\%}) and a specificity of 100{\%} (95{\%} confidence interval, 83{\%}-100{\%}). Conclusions: In this small study, bedside ultrasound appears to be highly sensitive and specific in differentiating intra- versus extrathoracic chest tube placement.",
author = "Salz, {Toby O.} and Wilson, {Sharon R.} and Otto Liebmann and Price, {Daniel D.}",
year = "2010",
month = "6",
doi = "10.1016/j.ajem.2009.04.010",
language = "English (US)",
volume = "28",
pages = "626--630",
journal = "American Journal of Emergency Medicine",
issn = "0735-6757",
publisher = "W.B. Saunders Ltd",
number = "5",

}

TY - JOUR

T1 - An initial description of a sonographic sign that verifies intrathoracic chest tube placement

AU - Salz, Toby O.

AU - Wilson, Sharon R.

AU - Liebmann, Otto

AU - Price, Daniel D.

PY - 2010/6

Y1 - 2010/6

N2 - Purpose: An initial description of a sonographic finding predictive of intrathoracic chest tube placement. Methods: This was a prospective observational study using unembalmed cadaveric models. Chest tubes were randomly placed intra- and extrathoracically and evaluated using ultrasound. Chest tube location was confirmed using blunt dissection followed by tactile and visual confirmation. Sonographers were blinded to chest tube position. Sonographic images obtained in a transverse orientation revealed a subcutaneous hyperechoic arc, created by the chest tube, at the insertion site. The path of the hyperechoic arc was followed cephalad. Disappearance of the hyperechoic arc signified intrathoracic chest tube placement. In contrast, continuation of a subcutaneous hyperechoic arc for the full length of the chest tube signified extrathoracic chest tube placement (the Disappearance/Intrathoracic, Continuation/Extrathoracic sign). Results: Ultrasound was used to evaluate 48 chest tube placements. All chest tube locations were identified correctly. In differentiating intra- vs extrathoracic chest tube placement, the Disappearance/Intrathoracic, Continuation/Extrathoracic sign revealed a sensitivity of 100% (95% confidence interval, 83%-100%) and a specificity of 100% (95% confidence interval, 83%-100%). Conclusions: In this small study, bedside ultrasound appears to be highly sensitive and specific in differentiating intra- versus extrathoracic chest tube placement.

AB - Purpose: An initial description of a sonographic finding predictive of intrathoracic chest tube placement. Methods: This was a prospective observational study using unembalmed cadaveric models. Chest tubes were randomly placed intra- and extrathoracically and evaluated using ultrasound. Chest tube location was confirmed using blunt dissection followed by tactile and visual confirmation. Sonographers were blinded to chest tube position. Sonographic images obtained in a transverse orientation revealed a subcutaneous hyperechoic arc, created by the chest tube, at the insertion site. The path of the hyperechoic arc was followed cephalad. Disappearance of the hyperechoic arc signified intrathoracic chest tube placement. In contrast, continuation of a subcutaneous hyperechoic arc for the full length of the chest tube signified extrathoracic chest tube placement (the Disappearance/Intrathoracic, Continuation/Extrathoracic sign). Results: Ultrasound was used to evaluate 48 chest tube placements. All chest tube locations were identified correctly. In differentiating intra- vs extrathoracic chest tube placement, the Disappearance/Intrathoracic, Continuation/Extrathoracic sign revealed a sensitivity of 100% (95% confidence interval, 83%-100%) and a specificity of 100% (95% confidence interval, 83%-100%). Conclusions: In this small study, bedside ultrasound appears to be highly sensitive and specific in differentiating intra- versus extrathoracic chest tube placement.

UR - http://www.scopus.com/inward/record.url?scp=77953296047&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77953296047&partnerID=8YFLogxK

U2 - 10.1016/j.ajem.2009.04.010

DO - 10.1016/j.ajem.2009.04.010

M3 - Article

C2 - 20579562

AN - SCOPUS:77953296047

VL - 28

SP - 626

EP - 630

JO - American Journal of Emergency Medicine

JF - American Journal of Emergency Medicine

SN - 0735-6757

IS - 5

ER -