Aerosol Deposition: Practical Considerations of Methodology for the Direct Measurement of Aerosol Delivery to the Lung Bronchiolar-Alveolar Surfaces

Carroll E Cross, William J. Hornof, Philip D. Koblik, Paul E. Fisher

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

There is an increasing scientific and medical awareness that the efficiency of aerosol delivery to the peripheral lung parenchyma is variable. Recently, the concept of direct calculation of the amount of a radiolabeled nebulizer solution deposited in the lung has been described. This method uses calibrating intravenous doses of radiolabeled macroaggregated albumin to convert scintigraphically obtained lung region-of-interest counts to units of radioactivity. By measuring the amount of activity loaded into the nebulizer, this conversion permits calculation of the percentage of the initial nebulizer dose that was actually deposited in the lung. Some practical considerations and limitations of applying this nuclear medicine methodology to investigate the deliverability of radiolabeled substances in a nebulizer to the gas exchange regions of the lung are discussed.

Original languageEnglish (US)
Pages (from-to)39-45
Number of pages7
JournalJournal of Aerosol Medicine: Deposition, Clearance, and Effects in the Lung
Volume5
Issue number1
DOIs
StatePublished - 1992

Fingerprint

Aerosols
Nebulizers and Vaporizers
Lung
Nuclear Medicine
Radioactivity
Albumins
Gases

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine
  • Pharmacology (medical)

Cite this

@article{8cc840d9768a45478aa3b48e35a27bbc,
title = "Aerosol Deposition: Practical Considerations of Methodology for the Direct Measurement of Aerosol Delivery to the Lung Bronchiolar-Alveolar Surfaces",
abstract = "There is an increasing scientific and medical awareness that the efficiency of aerosol delivery to the peripheral lung parenchyma is variable. Recently, the concept of direct calculation of the amount of a radiolabeled nebulizer solution deposited in the lung has been described. This method uses calibrating intravenous doses of radiolabeled macroaggregated albumin to convert scintigraphically obtained lung region-of-interest counts to units of radioactivity. By measuring the amount of activity loaded into the nebulizer, this conversion permits calculation of the percentage of the initial nebulizer dose that was actually deposited in the lung. Some practical considerations and limitations of applying this nuclear medicine methodology to investigate the deliverability of radiolabeled substances in a nebulizer to the gas exchange regions of the lung are discussed.",
author = "Cross, {Carroll E} and Hornof, {William J.} and Koblik, {Philip D.} and Fisher, {Paul E.}",
year = "1992",
doi = "10.1089/jam.1992.5.39",
language = "English (US)",
volume = "5",
pages = "39--45",
journal = "Journal of Aerosol Medicine and Pulmonary Drug Delivery",
issn = "1941-2711",
publisher = "Mary Ann Liebert Inc.",
number = "1",

}

TY - JOUR

T1 - Aerosol Deposition

T2 - Practical Considerations of Methodology for the Direct Measurement of Aerosol Delivery to the Lung Bronchiolar-Alveolar Surfaces

AU - Cross, Carroll E

AU - Hornof, William J.

AU - Koblik, Philip D.

AU - Fisher, Paul E.

PY - 1992

Y1 - 1992

N2 - There is an increasing scientific and medical awareness that the efficiency of aerosol delivery to the peripheral lung parenchyma is variable. Recently, the concept of direct calculation of the amount of a radiolabeled nebulizer solution deposited in the lung has been described. This method uses calibrating intravenous doses of radiolabeled macroaggregated albumin to convert scintigraphically obtained lung region-of-interest counts to units of radioactivity. By measuring the amount of activity loaded into the nebulizer, this conversion permits calculation of the percentage of the initial nebulizer dose that was actually deposited in the lung. Some practical considerations and limitations of applying this nuclear medicine methodology to investigate the deliverability of radiolabeled substances in a nebulizer to the gas exchange regions of the lung are discussed.

AB - There is an increasing scientific and medical awareness that the efficiency of aerosol delivery to the peripheral lung parenchyma is variable. Recently, the concept of direct calculation of the amount of a radiolabeled nebulizer solution deposited in the lung has been described. This method uses calibrating intravenous doses of radiolabeled macroaggregated albumin to convert scintigraphically obtained lung region-of-interest counts to units of radioactivity. By measuring the amount of activity loaded into the nebulizer, this conversion permits calculation of the percentage of the initial nebulizer dose that was actually deposited in the lung. Some practical considerations and limitations of applying this nuclear medicine methodology to investigate the deliverability of radiolabeled substances in a nebulizer to the gas exchange regions of the lung are discussed.

UR - http://www.scopus.com/inward/record.url?scp=85012457485&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85012457485&partnerID=8YFLogxK

U2 - 10.1089/jam.1992.5.39

DO - 10.1089/jam.1992.5.39

M3 - Article

AN - SCOPUS:85012457485

VL - 5

SP - 39

EP - 45

JO - Journal of Aerosol Medicine and Pulmonary Drug Delivery

JF - Journal of Aerosol Medicine and Pulmonary Drug Delivery

SN - 1941-2711

IS - 1

ER -