Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors

Omer P. Kocaoglu, Ravi Jonnal, Sangyeol Lee, Qiang Wang, Zhuolin Liu, Donald T. Miller

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Optical coherence tomography with adaptive optics (AO-OCT) is a noninvasive method for imaging the living retina at the microscopic level. We used AO-OCT technology to follow changes in cone photoreceptor outer segment (OS) length and reflectance. To substantially increase sensitivity of the length measurements, a novel phase retrieval technique was demonstrated, capable of detecting changes on a nanometer scale. We acquired volume videos of 0.65°x0.65° retinal patches at 1.5° temporal to the fovea over 75 and 105 minutes in two subjects. Volumes were dewarped and registered, after which the cone intensity, OS length, and referenced phase difference were tracked over time. The reflections from inner segment/OS junction (IS/OS) and posterior tips of OS (PT) showed significant intensity variations over time. In contrast, the OS length as measured from the intensity images did not change, indicative of a highly stable OS length at least down to the level of the system's axial resolution (3μm). Smaller axial changes, however, were detected with our phase retrieval technique. Specifically, the PT-IS/OS phase difference for the same cones showed significant variation, suggesting real sub-wavelength changes in OS length of 125±46 nm/hr for the 22 cones followed. We believe these length changes are due to the normal renewal process of the cone OS that elongate the OS at a rate of about 100 nm/hr. The phase difference measurements were strongly correlated among Alines within the same cone (0.65 radians standard deviation) corresponding to a length sensitivity of 31 nm, or ~100 times smaller than the axial resolution of our system.

Original languageEnglish (US)
Title of host publicationOphthalmic Technologies XXII
Volume8209
DOIs
StatePublished - Apr 2 2012
Externally publishedYes
EventOphthalmic Technologies XXII - San Francisco, CA, United States
Duration: Jan 21 2012Jan 22 2012

Other

OtherOphthalmic Technologies XXII
CountryUnited States
CitySan Francisco, CA
Period1/21/121/22/12

Fingerprint

photoreceptors
Adaptive optics
Optical tomography
Optical Coherence Tomography
adaptive optics
Cones
tomography
reflectance
Retinal Cone Photoreceptor Cells
cones
Retina
Technology
retrieval
fovea
Imaging techniques
retina
Wavelength
sensitivity
standard deviation

Keywords

  • Adaptive Optics
  • Cone Photoreceptors
  • Optical Coherence Tomography
  • Phase Sensitive Imaging

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Electronic, Optical and Magnetic Materials
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Cite this

Kocaoglu, O. P., Jonnal, R., Lee, S., Wang, Q., Liu, Z., & Miller, D. T. (2012). Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors. In Ophthalmic Technologies XXII (Vol. 8209). [82091I] https://doi.org/10.1117/12.910530

Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors. / Kocaoglu, Omer P.; Jonnal, Ravi; Lee, Sangyeol; Wang, Qiang; Liu, Zhuolin; Miller, Donald T.

Ophthalmic Technologies XXII. Vol. 8209 2012. 82091I.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kocaoglu, OP, Jonnal, R, Lee, S, Wang, Q, Liu, Z & Miller, DT 2012, Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors. in Ophthalmic Technologies XXII. vol. 8209, 82091I, Ophthalmic Technologies XXII, San Francisco, CA, United States, 1/21/12. https://doi.org/10.1117/12.910530
Kocaoglu OP, Jonnal R, Lee S, Wang Q, Liu Z, Miller DT. Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors. In Ophthalmic Technologies XXII. Vol. 8209. 2012. 82091I https://doi.org/10.1117/12.910530
Kocaoglu, Omer P. ; Jonnal, Ravi ; Lee, Sangyeol ; Wang, Qiang ; Liu, Zhuolin ; Miller, Donald T. / Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors. Ophthalmic Technologies XXII. Vol. 8209 2012.
@inproceedings{bf6f926e6af944e0bcabd401ced91e98,
title = "Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors",
abstract = "Optical coherence tomography with adaptive optics (AO-OCT) is a noninvasive method for imaging the living retina at the microscopic level. We used AO-OCT technology to follow changes in cone photoreceptor outer segment (OS) length and reflectance. To substantially increase sensitivity of the length measurements, a novel phase retrieval technique was demonstrated, capable of detecting changes on a nanometer scale. We acquired volume videos of 0.65°x0.65° retinal patches at 1.5° temporal to the fovea over 75 and 105 minutes in two subjects. Volumes were dewarped and registered, after which the cone intensity, OS length, and referenced phase difference were tracked over time. The reflections from inner segment/OS junction (IS/OS) and posterior tips of OS (PT) showed significant intensity variations over time. In contrast, the OS length as measured from the intensity images did not change, indicative of a highly stable OS length at least down to the level of the system's axial resolution (3μm). Smaller axial changes, however, were detected with our phase retrieval technique. Specifically, the PT-IS/OS phase difference for the same cones showed significant variation, suggesting real sub-wavelength changes in OS length of 125±46 nm/hr for the 22 cones followed. We believe these length changes are due to the normal renewal process of the cone OS that elongate the OS at a rate of about 100 nm/hr. The phase difference measurements were strongly correlated among Alines within the same cone (0.65 radians standard deviation) corresponding to a length sensitivity of 31 nm, or ~100 times smaller than the axial resolution of our system.",
keywords = "Adaptive Optics, Cone Photoreceptors, Optical Coherence Tomography, Phase Sensitive Imaging",
author = "Kocaoglu, {Omer P.} and Ravi Jonnal and Sangyeol Lee and Qiang Wang and Zhuolin Liu and Miller, {Donald T.}",
year = "2012",
month = "4",
day = "2",
doi = "10.1117/12.910530",
language = "English (US)",
isbn = "9780819488527",
volume = "8209",
booktitle = "Ophthalmic Technologies XXII",

}

TY - GEN

T1 - Adaptive optics optical coherence tomography for measuring phase and reflectance dynamics of photoreceptors

AU - Kocaoglu, Omer P.

AU - Jonnal, Ravi

AU - Lee, Sangyeol

AU - Wang, Qiang

AU - Liu, Zhuolin

AU - Miller, Donald T.

PY - 2012/4/2

Y1 - 2012/4/2

N2 - Optical coherence tomography with adaptive optics (AO-OCT) is a noninvasive method for imaging the living retina at the microscopic level. We used AO-OCT technology to follow changes in cone photoreceptor outer segment (OS) length and reflectance. To substantially increase sensitivity of the length measurements, a novel phase retrieval technique was demonstrated, capable of detecting changes on a nanometer scale. We acquired volume videos of 0.65°x0.65° retinal patches at 1.5° temporal to the fovea over 75 and 105 minutes in two subjects. Volumes were dewarped and registered, after which the cone intensity, OS length, and referenced phase difference were tracked over time. The reflections from inner segment/OS junction (IS/OS) and posterior tips of OS (PT) showed significant intensity variations over time. In contrast, the OS length as measured from the intensity images did not change, indicative of a highly stable OS length at least down to the level of the system's axial resolution (3μm). Smaller axial changes, however, were detected with our phase retrieval technique. Specifically, the PT-IS/OS phase difference for the same cones showed significant variation, suggesting real sub-wavelength changes in OS length of 125±46 nm/hr for the 22 cones followed. We believe these length changes are due to the normal renewal process of the cone OS that elongate the OS at a rate of about 100 nm/hr. The phase difference measurements were strongly correlated among Alines within the same cone (0.65 radians standard deviation) corresponding to a length sensitivity of 31 nm, or ~100 times smaller than the axial resolution of our system.

AB - Optical coherence tomography with adaptive optics (AO-OCT) is a noninvasive method for imaging the living retina at the microscopic level. We used AO-OCT technology to follow changes in cone photoreceptor outer segment (OS) length and reflectance. To substantially increase sensitivity of the length measurements, a novel phase retrieval technique was demonstrated, capable of detecting changes on a nanometer scale. We acquired volume videos of 0.65°x0.65° retinal patches at 1.5° temporal to the fovea over 75 and 105 minutes in two subjects. Volumes were dewarped and registered, after which the cone intensity, OS length, and referenced phase difference were tracked over time. The reflections from inner segment/OS junction (IS/OS) and posterior tips of OS (PT) showed significant intensity variations over time. In contrast, the OS length as measured from the intensity images did not change, indicative of a highly stable OS length at least down to the level of the system's axial resolution (3μm). Smaller axial changes, however, were detected with our phase retrieval technique. Specifically, the PT-IS/OS phase difference for the same cones showed significant variation, suggesting real sub-wavelength changes in OS length of 125±46 nm/hr for the 22 cones followed. We believe these length changes are due to the normal renewal process of the cone OS that elongate the OS at a rate of about 100 nm/hr. The phase difference measurements were strongly correlated among Alines within the same cone (0.65 radians standard deviation) corresponding to a length sensitivity of 31 nm, or ~100 times smaller than the axial resolution of our system.

KW - Adaptive Optics

KW - Cone Photoreceptors

KW - Optical Coherence Tomography

KW - Phase Sensitive Imaging

UR - http://www.scopus.com/inward/record.url?scp=84859039216&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859039216&partnerID=8YFLogxK

U2 - 10.1117/12.910530

DO - 10.1117/12.910530

M3 - Conference contribution

AN - SCOPUS:84859039216

SN - 9780819488527

VL - 8209

BT - Ophthalmic Technologies XXII

ER -