Adaptive imaging for lesion detection using a zoom-in PET system

Jian Zhou, Jinyi Qi

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Positron emission tomography (PET) has become a leading modality in molecular imaging. Demands for further improvements in spatial resolution and sensitivity remain high with growing number of applications. In this paper we present a novel PET system design that integrates a high-resolution depth-of-interaction (DOI) detector into an existing PET system to obtain higher-resolution and higher-sensitivity images in a target region around the face of the high-resolution detector. A unique feature of the proposed PET system is that the high-resolution detector can be adaptively positioned based on the detectability or quantitative accuracy of a feature of interest. This paper focuses on the signal-known-exactly, background-known-exactly (SKE-BKE) detection task. We perform theoretical analysis of lesion detectability using computer observers, and then develop methods that can efficiently calculate the optimal position of the high-resolution detector that maximizes the lesion detectability. We simulated incorporation of a high-resolution DOI detector into the microPET II scanner. Quantitative results verified that the new system has better performance than the microPET II scanner in terms of spatial resolution and lesion detectability, and that the optimal position for lesion detection can be reliably predicted by the proposed method.

Original languageEnglish (US)
Article number5545440
Pages (from-to)119-130
Number of pages12
JournalIEEE Transactions on Medical Imaging
Volume30
Issue number1
DOIs
StatePublished - Jan 2011

Fingerprint

Positron emission tomography
Positron-Emission Tomography
Detectors
Imaging techniques
Molecular Imaging
Molecular imaging
Systems analysis

Keywords

  • Adaptive imaging
  • image reconstruction
  • lesion detection
  • positron emission tomography (PET)

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Computer Science Applications
  • Radiological and Ultrasound Technology
  • Software

Cite this

Adaptive imaging for lesion detection using a zoom-in PET system. / Zhou, Jian; Qi, Jinyi.

In: IEEE Transactions on Medical Imaging, Vol. 30, No. 1, 5545440, 01.2011, p. 119-130.

Research output: Contribution to journalArticle

Zhou, Jian ; Qi, Jinyi. / Adaptive imaging for lesion detection using a zoom-in PET system. In: IEEE Transactions on Medical Imaging. 2011 ; Vol. 30, No. 1. pp. 119-130.
@article{99de57322fd14a52abea31f3677bc011,
title = "Adaptive imaging for lesion detection using a zoom-in PET system",
abstract = "Positron emission tomography (PET) has become a leading modality in molecular imaging. Demands for further improvements in spatial resolution and sensitivity remain high with growing number of applications. In this paper we present a novel PET system design that integrates a high-resolution depth-of-interaction (DOI) detector into an existing PET system to obtain higher-resolution and higher-sensitivity images in a target region around the face of the high-resolution detector. A unique feature of the proposed PET system is that the high-resolution detector can be adaptively positioned based on the detectability or quantitative accuracy of a feature of interest. This paper focuses on the signal-known-exactly, background-known-exactly (SKE-BKE) detection task. We perform theoretical analysis of lesion detectability using computer observers, and then develop methods that can efficiently calculate the optimal position of the high-resolution detector that maximizes the lesion detectability. We simulated incorporation of a high-resolution DOI detector into the microPET II scanner. Quantitative results verified that the new system has better performance than the microPET II scanner in terms of spatial resolution and lesion detectability, and that the optimal position for lesion detection can be reliably predicted by the proposed method.",
keywords = "Adaptive imaging, image reconstruction, lesion detection, positron emission tomography (PET)",
author = "Jian Zhou and Jinyi Qi",
year = "2011",
month = "1",
doi = "10.1109/TMI.2010.2064173",
language = "English (US)",
volume = "30",
pages = "119--130",
journal = "IEEE Transactions on Medical Imaging",
issn = "0278-0062",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

TY - JOUR

T1 - Adaptive imaging for lesion detection using a zoom-in PET system

AU - Zhou, Jian

AU - Qi, Jinyi

PY - 2011/1

Y1 - 2011/1

N2 - Positron emission tomography (PET) has become a leading modality in molecular imaging. Demands for further improvements in spatial resolution and sensitivity remain high with growing number of applications. In this paper we present a novel PET system design that integrates a high-resolution depth-of-interaction (DOI) detector into an existing PET system to obtain higher-resolution and higher-sensitivity images in a target region around the face of the high-resolution detector. A unique feature of the proposed PET system is that the high-resolution detector can be adaptively positioned based on the detectability or quantitative accuracy of a feature of interest. This paper focuses on the signal-known-exactly, background-known-exactly (SKE-BKE) detection task. We perform theoretical analysis of lesion detectability using computer observers, and then develop methods that can efficiently calculate the optimal position of the high-resolution detector that maximizes the lesion detectability. We simulated incorporation of a high-resolution DOI detector into the microPET II scanner. Quantitative results verified that the new system has better performance than the microPET II scanner in terms of spatial resolution and lesion detectability, and that the optimal position for lesion detection can be reliably predicted by the proposed method.

AB - Positron emission tomography (PET) has become a leading modality in molecular imaging. Demands for further improvements in spatial resolution and sensitivity remain high with growing number of applications. In this paper we present a novel PET system design that integrates a high-resolution depth-of-interaction (DOI) detector into an existing PET system to obtain higher-resolution and higher-sensitivity images in a target region around the face of the high-resolution detector. A unique feature of the proposed PET system is that the high-resolution detector can be adaptively positioned based on the detectability or quantitative accuracy of a feature of interest. This paper focuses on the signal-known-exactly, background-known-exactly (SKE-BKE) detection task. We perform theoretical analysis of lesion detectability using computer observers, and then develop methods that can efficiently calculate the optimal position of the high-resolution detector that maximizes the lesion detectability. We simulated incorporation of a high-resolution DOI detector into the microPET II scanner. Quantitative results verified that the new system has better performance than the microPET II scanner in terms of spatial resolution and lesion detectability, and that the optimal position for lesion detection can be reliably predicted by the proposed method.

KW - Adaptive imaging

KW - image reconstruction

KW - lesion detection

KW - positron emission tomography (PET)

UR - http://www.scopus.com/inward/record.url?scp=78650924373&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78650924373&partnerID=8YFLogxK

U2 - 10.1109/TMI.2010.2064173

DO - 10.1109/TMI.2010.2064173

M3 - Article

VL - 30

SP - 119

EP - 130

JO - IEEE Transactions on Medical Imaging

JF - IEEE Transactions on Medical Imaging

SN - 0278-0062

IS - 1

M1 - 5545440

ER -