Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach

P. Krishna Kumar, Tadashi Araki, Jeny Rajan, Luca Saba, Francesco Lavra, Nobutaka Ikeda, Aditya M. Sharma, Shoaib Shafique, Andrew Nicolaides, John R. Laird, Ajay Gupta, Jasjit S. Suri

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients’ left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system.

Original languageEnglish (US)
Pages (from-to)1-20
Number of pages20
JournalMedical and Biological Engineering and Computing
DOIs
StateAccepted/In press - Dec 10 2016

Fingerprint

Ultrasonics
Statistical tests
Monitoring

Keywords

  • B-mode ultrasound
  • Carotid artery
  • Curved vessels
  • Lumen diameter
  • Scale-space
  • Transformation

ASJC Scopus subject areas

  • Biomedical Engineering
  • Computer Science Applications

Cite this

Accurate lumen diameter measurement in curved vessels in carotid ultrasound : an iterative scale-space and spatial transformation approach. / Krishna Kumar, P.; Araki, Tadashi; Rajan, Jeny; Saba, Luca; Lavra, Francesco; Ikeda, Nobutaka; Sharma, Aditya M.; Shafique, Shoaib; Nicolaides, Andrew; Laird, John R.; Gupta, Ajay; Suri, Jasjit S.

In: Medical and Biological Engineering and Computing, 10.12.2016, p. 1-20.

Research output: Contribution to journalArticle

Krishna Kumar, P, Araki, T, Rajan, J, Saba, L, Lavra, F, Ikeda, N, Sharma, AM, Shafique, S, Nicolaides, A, Laird, JR, Gupta, A & Suri, JS 2016, 'Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach', Medical and Biological Engineering and Computing, pp. 1-20. https://doi.org/10.1007/s11517-016-1601-y
Krishna Kumar, P. ; Araki, Tadashi ; Rajan, Jeny ; Saba, Luca ; Lavra, Francesco ; Ikeda, Nobutaka ; Sharma, Aditya M. ; Shafique, Shoaib ; Nicolaides, Andrew ; Laird, John R. ; Gupta, Ajay ; Suri, Jasjit S. / Accurate lumen diameter measurement in curved vessels in carotid ultrasound : an iterative scale-space and spatial transformation approach. In: Medical and Biological Engineering and Computing. 2016 ; pp. 1-20.
@article{b3a38bfcb7cc406e8f607d9ddc796d63,
title = "Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach",
abstract = "Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients’ left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7{\%}, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system.",
keywords = "B-mode ultrasound, Carotid artery, Curved vessels, Lumen diameter, Scale-space, Transformation",
author = "{Krishna Kumar}, P. and Tadashi Araki and Jeny Rajan and Luca Saba and Francesco Lavra and Nobutaka Ikeda and Sharma, {Aditya M.} and Shoaib Shafique and Andrew Nicolaides and Laird, {John R.} and Ajay Gupta and Suri, {Jasjit S.}",
year = "2016",
month = "12",
day = "10",
doi = "10.1007/s11517-016-1601-y",
language = "English (US)",
pages = "1--20",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",

}

TY - JOUR

T1 - Accurate lumen diameter measurement in curved vessels in carotid ultrasound

T2 - an iterative scale-space and spatial transformation approach

AU - Krishna Kumar, P.

AU - Araki, Tadashi

AU - Rajan, Jeny

AU - Saba, Luca

AU - Lavra, Francesco

AU - Ikeda, Nobutaka

AU - Sharma, Aditya M.

AU - Shafique, Shoaib

AU - Nicolaides, Andrew

AU - Laird, John R.

AU - Gupta, Ajay

AU - Suri, Jasjit S.

PY - 2016/12/10

Y1 - 2016/12/10

N2 - Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients’ left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system.

AB - Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients’ left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system.

KW - B-mode ultrasound

KW - Carotid artery

KW - Curved vessels

KW - Lumen diameter

KW - Scale-space

KW - Transformation

UR - http://www.scopus.com/inward/record.url?scp=85006374918&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85006374918&partnerID=8YFLogxK

U2 - 10.1007/s11517-016-1601-y

DO - 10.1007/s11517-016-1601-y

M3 - Article

AN - SCOPUS:85006374918

SP - 1

EP - 20

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

ER -