Accuracy of cardiac output estimation with biplane transesophageal echocardiography.

T. Hozumi, M. Shakudo, Richard Lee Applegate, P. M. Shah

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

To evaluate the accuracy of cardiac output measurements with biplane transesophageal Doppler echocardiography, we examined 26 sets of observations in 14 patients using thermodilution technique as the standard. A mitral inflow method by single-plane combined the time-velocity integral of mitral inflow at the mitral annulus with the area of mitral annulus, assuming it to be a circular shape, by use of either the four- or the two-chamber view. With both views, a mitral inflow method by biplane combined the average of time-velocity integral of mitral inflow from the four- and the two-chamber views with the area of mitral annulus, assuming it to be an ellipsoid shape. The correlation coefficients between thermodilution and single-plane method of cardiac output were 0.81 (SEE = 0.72 L/min) and 0.85 (SEE = 0.79 L/min) for the four- and the two-chamber views, respectively. The correlation coefficient with biplane method was 0.93 (SEE = 0.47 L/min). Thus, biplane transesophageal Doppler echocardiography can be used for more accurate estimation of cardiac output.

Original languageEnglish (US)
Pages (from-to)62-68
Number of pages7
JournalJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
Volume6
Issue number1
StatePublished - Jan 1993
Externally publishedYes

Fingerprint

Transesophageal Echocardiography
Cardiac Output
Thermodilution
Doppler Echocardiography

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging

Cite this

@article{5f9abeb32da14df1bc9d81e36b3b624f,
title = "Accuracy of cardiac output estimation with biplane transesophageal echocardiography.",
abstract = "To evaluate the accuracy of cardiac output measurements with biplane transesophageal Doppler echocardiography, we examined 26 sets of observations in 14 patients using thermodilution technique as the standard. A mitral inflow method by single-plane combined the time-velocity integral of mitral inflow at the mitral annulus with the area of mitral annulus, assuming it to be a circular shape, by use of either the four- or the two-chamber view. With both views, a mitral inflow method by biplane combined the average of time-velocity integral of mitral inflow from the four- and the two-chamber views with the area of mitral annulus, assuming it to be an ellipsoid shape. The correlation coefficients between thermodilution and single-plane method of cardiac output were 0.81 (SEE = 0.72 L/min) and 0.85 (SEE = 0.79 L/min) for the four- and the two-chamber views, respectively. The correlation coefficient with biplane method was 0.93 (SEE = 0.47 L/min). Thus, biplane transesophageal Doppler echocardiography can be used for more accurate estimation of cardiac output.",
author = "T. Hozumi and M. Shakudo and Applegate, {Richard Lee} and Shah, {P. M.}",
year = "1993",
month = "1",
language = "English (US)",
volume = "6",
pages = "62--68",
journal = "Journal of the American Society of Echocardiography",
issn = "0894-7317",
publisher = "Mosby Inc.",
number = "1",

}

TY - JOUR

T1 - Accuracy of cardiac output estimation with biplane transesophageal echocardiography.

AU - Hozumi, T.

AU - Shakudo, M.

AU - Applegate, Richard Lee

AU - Shah, P. M.

PY - 1993/1

Y1 - 1993/1

N2 - To evaluate the accuracy of cardiac output measurements with biplane transesophageal Doppler echocardiography, we examined 26 sets of observations in 14 patients using thermodilution technique as the standard. A mitral inflow method by single-plane combined the time-velocity integral of mitral inflow at the mitral annulus with the area of mitral annulus, assuming it to be a circular shape, by use of either the four- or the two-chamber view. With both views, a mitral inflow method by biplane combined the average of time-velocity integral of mitral inflow from the four- and the two-chamber views with the area of mitral annulus, assuming it to be an ellipsoid shape. The correlation coefficients between thermodilution and single-plane method of cardiac output were 0.81 (SEE = 0.72 L/min) and 0.85 (SEE = 0.79 L/min) for the four- and the two-chamber views, respectively. The correlation coefficient with biplane method was 0.93 (SEE = 0.47 L/min). Thus, biplane transesophageal Doppler echocardiography can be used for more accurate estimation of cardiac output.

AB - To evaluate the accuracy of cardiac output measurements with biplane transesophageal Doppler echocardiography, we examined 26 sets of observations in 14 patients using thermodilution technique as the standard. A mitral inflow method by single-plane combined the time-velocity integral of mitral inflow at the mitral annulus with the area of mitral annulus, assuming it to be a circular shape, by use of either the four- or the two-chamber view. With both views, a mitral inflow method by biplane combined the average of time-velocity integral of mitral inflow from the four- and the two-chamber views with the area of mitral annulus, assuming it to be an ellipsoid shape. The correlation coefficients between thermodilution and single-plane method of cardiac output were 0.81 (SEE = 0.72 L/min) and 0.85 (SEE = 0.79 L/min) for the four- and the two-chamber views, respectively. The correlation coefficient with biplane method was 0.93 (SEE = 0.47 L/min). Thus, biplane transesophageal Doppler echocardiography can be used for more accurate estimation of cardiac output.

UR - http://www.scopus.com/inward/record.url?scp=0027345619&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027345619&partnerID=8YFLogxK

M3 - Article

C2 - 8439424

AN - SCOPUS:0027345619

VL - 6

SP - 62

EP - 68

JO - Journal of the American Society of Echocardiography

JF - Journal of the American Society of Echocardiography

SN - 0894-7317

IS - 1

ER -