Absolute flow measurements using pulsed Doppler US. Work in progress

J. P. Walter, John P McGahan, B. M T Lantz

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

Quantitative flow measurements were assessed in both laboratory and canine models using pulsed Doppler ultrasonography (US). A hydrodynamic model consisting of a Harvard pulsatile pump, a water bath, tubing, and a variable resistance reservoir was used to obtain absolute volumetric flow measurements. Parameters including angle of incidence, size of tubing, stroke volume, stroke rate, sample volume, and transducer frequency were changed independently. The effect of varying these parameters on the determination of absolute flow was analyzed. Absolute flow measurements using duplex US were performed in the canine aorta and femoral artery with reference to the electromagnetic flow probe. These data are presented, along with methods to reduce error in flow measurements that can be directly applied to quantitative estimates of blood flow in humans.

Original languageEnglish (US)
Pages (from-to)545-548
Number of pages4
JournalRadiology
Volume159
Issue number2
StatePublished - 1986

Fingerprint

Doppler Pulsed Ultrasonography
Canidae
Electromagnetic Phenomena
Femoral Artery
Hydrodynamics
Transducers
Baths
Stroke Volume
Aorta
Ultrasonography
Stroke
Water
Incidence

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Walter, J. P., McGahan, J. P., & Lantz, B. M. T. (1986). Absolute flow measurements using pulsed Doppler US. Work in progress. Radiology, 159(2), 545-548.

Absolute flow measurements using pulsed Doppler US. Work in progress. / Walter, J. P.; McGahan, John P; Lantz, B. M T.

In: Radiology, Vol. 159, No. 2, 1986, p. 545-548.

Research output: Contribution to journalArticle

Walter, JP, McGahan, JP & Lantz, BMT 1986, 'Absolute flow measurements using pulsed Doppler US. Work in progress', Radiology, vol. 159, no. 2, pp. 545-548.
Walter, J. P. ; McGahan, John P ; Lantz, B. M T. / Absolute flow measurements using pulsed Doppler US. Work in progress. In: Radiology. 1986 ; Vol. 159, No. 2. pp. 545-548.
@article{7a2e585e7fe94089a5f1ef9302141562,
title = "Absolute flow measurements using pulsed Doppler US. Work in progress",
abstract = "Quantitative flow measurements were assessed in both laboratory and canine models using pulsed Doppler ultrasonography (US). A hydrodynamic model consisting of a Harvard pulsatile pump, a water bath, tubing, and a variable resistance reservoir was used to obtain absolute volumetric flow measurements. Parameters including angle of incidence, size of tubing, stroke volume, stroke rate, sample volume, and transducer frequency were changed independently. The effect of varying these parameters on the determination of absolute flow was analyzed. Absolute flow measurements using duplex US were performed in the canine aorta and femoral artery with reference to the electromagnetic flow probe. These data are presented, along with methods to reduce error in flow measurements that can be directly applied to quantitative estimates of blood flow in humans.",
author = "Walter, {J. P.} and McGahan, {John P} and Lantz, {B. M T}",
year = "1986",
language = "English (US)",
volume = "159",
pages = "545--548",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "2",

}

TY - JOUR

T1 - Absolute flow measurements using pulsed Doppler US. Work in progress

AU - Walter, J. P.

AU - McGahan, John P

AU - Lantz, B. M T

PY - 1986

Y1 - 1986

N2 - Quantitative flow measurements were assessed in both laboratory and canine models using pulsed Doppler ultrasonography (US). A hydrodynamic model consisting of a Harvard pulsatile pump, a water bath, tubing, and a variable resistance reservoir was used to obtain absolute volumetric flow measurements. Parameters including angle of incidence, size of tubing, stroke volume, stroke rate, sample volume, and transducer frequency were changed independently. The effect of varying these parameters on the determination of absolute flow was analyzed. Absolute flow measurements using duplex US were performed in the canine aorta and femoral artery with reference to the electromagnetic flow probe. These data are presented, along with methods to reduce error in flow measurements that can be directly applied to quantitative estimates of blood flow in humans.

AB - Quantitative flow measurements were assessed in both laboratory and canine models using pulsed Doppler ultrasonography (US). A hydrodynamic model consisting of a Harvard pulsatile pump, a water bath, tubing, and a variable resistance reservoir was used to obtain absolute volumetric flow measurements. Parameters including angle of incidence, size of tubing, stroke volume, stroke rate, sample volume, and transducer frequency were changed independently. The effect of varying these parameters on the determination of absolute flow was analyzed. Absolute flow measurements using duplex US were performed in the canine aorta and femoral artery with reference to the electromagnetic flow probe. These data are presented, along with methods to reduce error in flow measurements that can be directly applied to quantitative estimates of blood flow in humans.

UR - http://www.scopus.com/inward/record.url?scp=0022591487&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022591487&partnerID=8YFLogxK

M3 - Article

VL - 159

SP - 545

EP - 548

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 2