A simple technique to characterize proximal and peripheral nitric oxide exchange using constant flow exhalations and an axial diffusion model

Peter Condorelli, Hye Won Shin, Anna S. Aledia, Philip E. Silkoff, Steven George

Research output: Contribution to journalArticle

147 Citations (Scopus)

Abstract

The most common technique employed to describe pulmonary gas exchange of nitric oxide (NO) combines multiple constant flow exhalations with a two-compartment model (2CM) that neglects 1) the trumpet shape (increasing surface area per unit volume) of the airway tree and 2) gas phase axial diffusion of NO. However, recent evidence suggests that these features of the lungs are important determinants of NO exchange. The goal of this study is to present an algorithm that characterizes NO exchange using multiple constant flow exhalations and a model that considers the trumpet shape of the airway tree and axial diffusion (model TMAD). Solution of the diffusion equation for the TMAD for exhalation flows >100 ml/s can be reduced to the same linear relationship between the NO elimination rate and the flow; however, the interpretation of the slope and the intercept depend on the model. We tested the TMAD in healthy subjects (n = 8) using commonly used and easily performed exhalation flows (100, 150, 200, and 250 ml/s). Compared with the 2CM, estimates (mean ± SD) from the TMAD for the maximum airway flux are statistically higher (J′awNO = 770 ± 470 compared with 440 ± 270 pl/s), whereas estimates for the steady-state alveolar concentration are statistically lower (CANO = 0.66 ± 0.98 compared with 1.2 ± 0.80 parts/billion). Furthermore, CANO from the TMAD is not different from zero. We conclude that proximal (airways) NO production is larger than previously predicted with the 2CM and that peripheral (respiratory bronchioles and alveoli) NO is near zero in healthy subjects.

Original languageEnglish (US)
Pages (from-to)417-425
Number of pages9
JournalJournal of Applied Physiology
Volume102
Issue number1
DOIs
StatePublished - Jan 1 2007

Fingerprint

Exhalation
Nitric Oxide
Healthy Volunteers
Pulmonary Gas Exchange
Bronchioles
Gases
Lung

Keywords

  • Airway
  • Alveolar
  • Model

ASJC Scopus subject areas

  • Physiology
  • Physiology (medical)

Cite this

A simple technique to characterize proximal and peripheral nitric oxide exchange using constant flow exhalations and an axial diffusion model. / Condorelli, Peter; Shin, Hye Won; Aledia, Anna S.; Silkoff, Philip E.; George, Steven.

In: Journal of Applied Physiology, Vol. 102, No. 1, 01.01.2007, p. 417-425.

Research output: Contribution to journalArticle

@article{a8eca8a8a79a41bfa53b780fe2c140c6,
title = "A simple technique to characterize proximal and peripheral nitric oxide exchange using constant flow exhalations and an axial diffusion model",
abstract = "The most common technique employed to describe pulmonary gas exchange of nitric oxide (NO) combines multiple constant flow exhalations with a two-compartment model (2CM) that neglects 1) the trumpet shape (increasing surface area per unit volume) of the airway tree and 2) gas phase axial diffusion of NO. However, recent evidence suggests that these features of the lungs are important determinants of NO exchange. The goal of this study is to present an algorithm that characterizes NO exchange using multiple constant flow exhalations and a model that considers the trumpet shape of the airway tree and axial diffusion (model TMAD). Solution of the diffusion equation for the TMAD for exhalation flows >100 ml/s can be reduced to the same linear relationship between the NO elimination rate and the flow; however, the interpretation of the slope and the intercept depend on the model. We tested the TMAD in healthy subjects (n = 8) using commonly used and easily performed exhalation flows (100, 150, 200, and 250 ml/s). Compared with the 2CM, estimates (mean ± SD) from the TMAD for the maximum airway flux are statistically higher (J′awNO = 770 ± 470 compared with 440 ± 270 pl/s), whereas estimates for the steady-state alveolar concentration are statistically lower (CANO = 0.66 ± 0.98 compared with 1.2 ± 0.80 parts/billion). Furthermore, CANO from the TMAD is not different from zero. We conclude that proximal (airways) NO production is larger than previously predicted with the 2CM and that peripheral (respiratory bronchioles and alveoli) NO is near zero in healthy subjects.",
keywords = "Airway, Alveolar, Model",
author = "Peter Condorelli and Shin, {Hye Won} and Aledia, {Anna S.} and Silkoff, {Philip E.} and Steven George",
year = "2007",
month = "1",
day = "1",
doi = "10.1152/japplphysiol.00533.2006",
language = "English (US)",
volume = "102",
pages = "417--425",
journal = "Journal of Applied Physiology",
issn = "8750-7587",
publisher = "American Physiological Society",
number = "1",

}

TY - JOUR

T1 - A simple technique to characterize proximal and peripheral nitric oxide exchange using constant flow exhalations and an axial diffusion model

AU - Condorelli, Peter

AU - Shin, Hye Won

AU - Aledia, Anna S.

AU - Silkoff, Philip E.

AU - George, Steven

PY - 2007/1/1

Y1 - 2007/1/1

N2 - The most common technique employed to describe pulmonary gas exchange of nitric oxide (NO) combines multiple constant flow exhalations with a two-compartment model (2CM) that neglects 1) the trumpet shape (increasing surface area per unit volume) of the airway tree and 2) gas phase axial diffusion of NO. However, recent evidence suggests that these features of the lungs are important determinants of NO exchange. The goal of this study is to present an algorithm that characterizes NO exchange using multiple constant flow exhalations and a model that considers the trumpet shape of the airway tree and axial diffusion (model TMAD). Solution of the diffusion equation for the TMAD for exhalation flows >100 ml/s can be reduced to the same linear relationship between the NO elimination rate and the flow; however, the interpretation of the slope and the intercept depend on the model. We tested the TMAD in healthy subjects (n = 8) using commonly used and easily performed exhalation flows (100, 150, 200, and 250 ml/s). Compared with the 2CM, estimates (mean ± SD) from the TMAD for the maximum airway flux are statistically higher (J′awNO = 770 ± 470 compared with 440 ± 270 pl/s), whereas estimates for the steady-state alveolar concentration are statistically lower (CANO = 0.66 ± 0.98 compared with 1.2 ± 0.80 parts/billion). Furthermore, CANO from the TMAD is not different from zero. We conclude that proximal (airways) NO production is larger than previously predicted with the 2CM and that peripheral (respiratory bronchioles and alveoli) NO is near zero in healthy subjects.

AB - The most common technique employed to describe pulmonary gas exchange of nitric oxide (NO) combines multiple constant flow exhalations with a two-compartment model (2CM) that neglects 1) the trumpet shape (increasing surface area per unit volume) of the airway tree and 2) gas phase axial diffusion of NO. However, recent evidence suggests that these features of the lungs are important determinants of NO exchange. The goal of this study is to present an algorithm that characterizes NO exchange using multiple constant flow exhalations and a model that considers the trumpet shape of the airway tree and axial diffusion (model TMAD). Solution of the diffusion equation for the TMAD for exhalation flows >100 ml/s can be reduced to the same linear relationship between the NO elimination rate and the flow; however, the interpretation of the slope and the intercept depend on the model. We tested the TMAD in healthy subjects (n = 8) using commonly used and easily performed exhalation flows (100, 150, 200, and 250 ml/s). Compared with the 2CM, estimates (mean ± SD) from the TMAD for the maximum airway flux are statistically higher (J′awNO = 770 ± 470 compared with 440 ± 270 pl/s), whereas estimates for the steady-state alveolar concentration are statistically lower (CANO = 0.66 ± 0.98 compared with 1.2 ± 0.80 parts/billion). Furthermore, CANO from the TMAD is not different from zero. We conclude that proximal (airways) NO production is larger than previously predicted with the 2CM and that peripheral (respiratory bronchioles and alveoli) NO is near zero in healthy subjects.

KW - Airway

KW - Alveolar

KW - Model

UR - http://www.scopus.com/inward/record.url?scp=33846178236&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33846178236&partnerID=8YFLogxK

U2 - 10.1152/japplphysiol.00533.2006

DO - 10.1152/japplphysiol.00533.2006

M3 - Article

C2 - 16888048

AN - SCOPUS:33846178236

VL - 102

SP - 417

EP - 425

JO - Journal of Applied Physiology

JF - Journal of Applied Physiology

SN - 8750-7587

IS - 1

ER -