A highly sensitive and rapid ELISA for the arylurea herbicides diuron, monuron, and linuron

Peter Schneider, Marvin H. Goodrow, Shirley J. Gee, Bruce D. Hammock

Research output: Contribution to journalArticle

71 Citations (Scopus)

Abstract

A highly sensitive and rapid enzyme-linked immunosorbent assay (ELISA) for the detection of the arylurea herbicides monuron, diuron, and linuron is described. Diuron haptens with two different polymethylene handle locations were evaluated for use as immunizing and/or tracer antigens. One handle, consisting of three or five methylene groups, located at the terminal urea nitrogen distal to the aromatic ring provided the best antibodies and enzyme-labeled haptens with a variety of selectivities. The second methylene handle attachment at the internal urea nitrogen retained the basic structure of the target molecule, but was not recognized by the antibodies produced from the terminal substituted haptens, nor was it useful as an enzyme tracer. Rabbits were immunized with monuron hapten-bovine serum albumin conjugates that contained either a C3 or C5 methylene handle at the terminal nitrogen. The resulting selectivity of the antisera was not related to the immunizing antigen used. The analyses were class or compound selective for the individual herbicides depending upon the antisera used. Widely applied urea herbicides such as diuron, monuron, and linuron demonstrated 50% inhibition values at 0.4, 0.5, and 0.8 μg/L and detection limits of 0.04, 0.05, and 0.08 μg/L, respectively, in buffer. The test, applied to matrices such as water and orange juice, showed limited matrix effects which could be eliminated by moderate dilution of the sample. The assays were tested for tolerance to methanol, a commonly used solvent in the extraction of diuron from environmental matrices. Up to 50% methanol in the assay had no effect on assay parameters such as the 50% inhibition values. To develop a rational approach for the selection of a hapten for use as an enzyme tracer, a variety of monuron, diuron, and linuron haptens were tested for cross reactivity. Some of these same haptens were then used as hapten enzyme conjugates. In general, haptens recognized about 100 times less well than the "best" hapten were useful as enzyme tracers. In addition, we found that cross reactivity data for esters of carboxylic acid haptens may be better predictors of the binding of the carboxylic acids when conjugated as antigens or enzyme tracers.

Original languageEnglish (US)
Pages (from-to)413-422
Number of pages10
JournalJournal of Agricultural and Food Chemistry
Volume42
Issue number2
StatePublished - 1994

Fingerprint

Linuron
monuron
Diuron
linuron
haptens
Immunosorbents
diuron
Haptens
Herbicides
Assays
herbicides
Enzyme-Linked Immunosorbent Assay
enzyme-linked immunosorbent assay
Enzymes
tracer techniques
enzymes
Urea
Nitrogen
carboxylic acids
Carboxylic Acids

ASJC Scopus subject areas

  • Agricultural and Biological Sciences (miscellaneous)
  • Food Science
  • Chemistry (miscellaneous)

Cite this

A highly sensitive and rapid ELISA for the arylurea herbicides diuron, monuron, and linuron. / Schneider, Peter; Goodrow, Marvin H.; Gee, Shirley J.; Hammock, Bruce D.

In: Journal of Agricultural and Food Chemistry, Vol. 42, No. 2, 1994, p. 413-422.

Research output: Contribution to journalArticle

Schneider, P, Goodrow, MH, Gee, SJ & Hammock, BD 1994, 'A highly sensitive and rapid ELISA for the arylurea herbicides diuron, monuron, and linuron', Journal of Agricultural and Food Chemistry, vol. 42, no. 2, pp. 413-422.
Schneider, Peter ; Goodrow, Marvin H. ; Gee, Shirley J. ; Hammock, Bruce D. / A highly sensitive and rapid ELISA for the arylurea herbicides diuron, monuron, and linuron. In: Journal of Agricultural and Food Chemistry. 1994 ; Vol. 42, No. 2. pp. 413-422.
@article{016c7dcc2c764fb6ad2e8ce5cc4e8878,
title = "A highly sensitive and rapid ELISA for the arylurea herbicides diuron, monuron, and linuron",
abstract = "A highly sensitive and rapid enzyme-linked immunosorbent assay (ELISA) for the detection of the arylurea herbicides monuron, diuron, and linuron is described. Diuron haptens with two different polymethylene handle locations were evaluated for use as immunizing and/or tracer antigens. One handle, consisting of three or five methylene groups, located at the terminal urea nitrogen distal to the aromatic ring provided the best antibodies and enzyme-labeled haptens with a variety of selectivities. The second methylene handle attachment at the internal urea nitrogen retained the basic structure of the target molecule, but was not recognized by the antibodies produced from the terminal substituted haptens, nor was it useful as an enzyme tracer. Rabbits were immunized with monuron hapten-bovine serum albumin conjugates that contained either a C3 or C5 methylene handle at the terminal nitrogen. The resulting selectivity of the antisera was not related to the immunizing antigen used. The analyses were class or compound selective for the individual herbicides depending upon the antisera used. Widely applied urea herbicides such as diuron, monuron, and linuron demonstrated 50{\%} inhibition values at 0.4, 0.5, and 0.8 μg/L and detection limits of 0.04, 0.05, and 0.08 μg/L, respectively, in buffer. The test, applied to matrices such as water and orange juice, showed limited matrix effects which could be eliminated by moderate dilution of the sample. The assays were tested for tolerance to methanol, a commonly used solvent in the extraction of diuron from environmental matrices. Up to 50{\%} methanol in the assay had no effect on assay parameters such as the 50{\%} inhibition values. To develop a rational approach for the selection of a hapten for use as an enzyme tracer, a variety of monuron, diuron, and linuron haptens were tested for cross reactivity. Some of these same haptens were then used as hapten enzyme conjugates. In general, haptens recognized about 100 times less well than the {"}best{"} hapten were useful as enzyme tracers. In addition, we found that cross reactivity data for esters of carboxylic acid haptens may be better predictors of the binding of the carboxylic acids when conjugated as antigens or enzyme tracers.",
author = "Peter Schneider and Goodrow, {Marvin H.} and Gee, {Shirley J.} and Hammock, {Bruce D.}",
year = "1994",
language = "English (US)",
volume = "42",
pages = "413--422",
journal = "Journal of Agricultural and Food Chemistry",
issn = "0021-8561",
publisher = "American Chemical Society",
number = "2",

}

TY - JOUR

T1 - A highly sensitive and rapid ELISA for the arylurea herbicides diuron, monuron, and linuron

AU - Schneider, Peter

AU - Goodrow, Marvin H.

AU - Gee, Shirley J.

AU - Hammock, Bruce D.

PY - 1994

Y1 - 1994

N2 - A highly sensitive and rapid enzyme-linked immunosorbent assay (ELISA) for the detection of the arylurea herbicides monuron, diuron, and linuron is described. Diuron haptens with two different polymethylene handle locations were evaluated for use as immunizing and/or tracer antigens. One handle, consisting of three or five methylene groups, located at the terminal urea nitrogen distal to the aromatic ring provided the best antibodies and enzyme-labeled haptens with a variety of selectivities. The second methylene handle attachment at the internal urea nitrogen retained the basic structure of the target molecule, but was not recognized by the antibodies produced from the terminal substituted haptens, nor was it useful as an enzyme tracer. Rabbits were immunized with monuron hapten-bovine serum albumin conjugates that contained either a C3 or C5 methylene handle at the terminal nitrogen. The resulting selectivity of the antisera was not related to the immunizing antigen used. The analyses were class or compound selective for the individual herbicides depending upon the antisera used. Widely applied urea herbicides such as diuron, monuron, and linuron demonstrated 50% inhibition values at 0.4, 0.5, and 0.8 μg/L and detection limits of 0.04, 0.05, and 0.08 μg/L, respectively, in buffer. The test, applied to matrices such as water and orange juice, showed limited matrix effects which could be eliminated by moderate dilution of the sample. The assays were tested for tolerance to methanol, a commonly used solvent in the extraction of diuron from environmental matrices. Up to 50% methanol in the assay had no effect on assay parameters such as the 50% inhibition values. To develop a rational approach for the selection of a hapten for use as an enzyme tracer, a variety of monuron, diuron, and linuron haptens were tested for cross reactivity. Some of these same haptens were then used as hapten enzyme conjugates. In general, haptens recognized about 100 times less well than the "best" hapten were useful as enzyme tracers. In addition, we found that cross reactivity data for esters of carboxylic acid haptens may be better predictors of the binding of the carboxylic acids when conjugated as antigens or enzyme tracers.

AB - A highly sensitive and rapid enzyme-linked immunosorbent assay (ELISA) for the detection of the arylurea herbicides monuron, diuron, and linuron is described. Diuron haptens with two different polymethylene handle locations were evaluated for use as immunizing and/or tracer antigens. One handle, consisting of three or five methylene groups, located at the terminal urea nitrogen distal to the aromatic ring provided the best antibodies and enzyme-labeled haptens with a variety of selectivities. The second methylene handle attachment at the internal urea nitrogen retained the basic structure of the target molecule, but was not recognized by the antibodies produced from the terminal substituted haptens, nor was it useful as an enzyme tracer. Rabbits were immunized with monuron hapten-bovine serum albumin conjugates that contained either a C3 or C5 methylene handle at the terminal nitrogen. The resulting selectivity of the antisera was not related to the immunizing antigen used. The analyses were class or compound selective for the individual herbicides depending upon the antisera used. Widely applied urea herbicides such as diuron, monuron, and linuron demonstrated 50% inhibition values at 0.4, 0.5, and 0.8 μg/L and detection limits of 0.04, 0.05, and 0.08 μg/L, respectively, in buffer. The test, applied to matrices such as water and orange juice, showed limited matrix effects which could be eliminated by moderate dilution of the sample. The assays were tested for tolerance to methanol, a commonly used solvent in the extraction of diuron from environmental matrices. Up to 50% methanol in the assay had no effect on assay parameters such as the 50% inhibition values. To develop a rational approach for the selection of a hapten for use as an enzyme tracer, a variety of monuron, diuron, and linuron haptens were tested for cross reactivity. Some of these same haptens were then used as hapten enzyme conjugates. In general, haptens recognized about 100 times less well than the "best" hapten were useful as enzyme tracers. In addition, we found that cross reactivity data for esters of carboxylic acid haptens may be better predictors of the binding of the carboxylic acids when conjugated as antigens or enzyme tracers.

UR - http://www.scopus.com/inward/record.url?scp=0345182822&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0345182822&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0345182822

VL - 42

SP - 413

EP - 422

JO - Journal of Agricultural and Food Chemistry

JF - Journal of Agricultural and Food Chemistry

SN - 0021-8561

IS - 2

ER -