3D gadolinium-enhanced MR angiography of the carotid arteries

Harry J. Cloft, Kieran J. Murphy, Martin R. Prince, James A Brunberg

Research output: Contribution to journalArticle

86 Citations (Scopus)

Abstract

Purpose: To compare gadolinium-enhanced magnetic resonance angiography (MRA) of the carotid bifurcation with 2D time-of-flight (TOF) MR angiography with regard to image quality and duration of examination. Materials and Methods: Gadolinium contrast was administered intravenously during 3D MR imaging at 1.5 Tesla in 46 patients presenting with suspected carotid occlusive disease. 2D time-of-flight MR angiography of the carotid bifurcation had been performed in each patient prior to gadolinium-enhanced MR angiography. Results: Gadolinium MRA eliminated slice misregistration and in-plane saturation artifacts that occasionally degrades 2D TOF MR angiography. Gadolinium MRA required less than 4 min to image from the aortic arch to the skull base compared to 11 min for 2D TOF with comparable signal- to-noise ratio (SNR). Postprocessing was required to eliminate overlapping venous enhancement. Both techniques had susceptibility related artifactual loss of signal at the skull base and both demonstrated a linear artifact paralleling the long axis of arteries. Conclusion: Gadolinium-enhanced MR angiography is a promising technique for the evaluation of patients with carotid occlusive disease because it rapidly images the carotid arteries from the aortic arch to the skull base and eliminates some of the artifacts that degrade 2D TOF MR angiography.

Original languageEnglish (US)
Pages (from-to)593-600
Number of pages8
JournalMagnetic Resonance Imaging
Volume14
Issue number6
DOIs
StatePublished - 1996
Externally publishedYes

Fingerprint

Angiography
angiography
Gadolinium
gadolinium
arteries
Carotid Arteries
Magnetic Resonance Angiography
Skull Base
Artifacts
skull
Magnetic resonance
Thoracic Aorta
magnetic resonance
artifacts
arches
Arches
Signal-To-Noise Ratio
Arteries
Image quality
Signal to noise ratio

Keywords

  • Arteries, MR
  • Carotid arteries, stenosis or obstruction
  • Magnetic resonance (MR), contrast enhancement
  • Magnetic resonance (MR), flow artifact
  • Magnetic resonance (MR), vascular studies

ASJC Scopus subject areas

  • Biophysics
  • Clinical Biochemistry
  • Structural Biology
  • Radiology Nuclear Medicine and imaging
  • Condensed Matter Physics

Cite this

3D gadolinium-enhanced MR angiography of the carotid arteries. / Cloft, Harry J.; Murphy, Kieran J.; Prince, Martin R.; Brunberg, James A.

In: Magnetic Resonance Imaging, Vol. 14, No. 6, 1996, p. 593-600.

Research output: Contribution to journalArticle

Cloft, Harry J. ; Murphy, Kieran J. ; Prince, Martin R. ; Brunberg, James A. / 3D gadolinium-enhanced MR angiography of the carotid arteries. In: Magnetic Resonance Imaging. 1996 ; Vol. 14, No. 6. pp. 593-600.
@article{b9ab40be7dc0457e92b800134f43930e,
title = "3D gadolinium-enhanced MR angiography of the carotid arteries",
abstract = "Purpose: To compare gadolinium-enhanced magnetic resonance angiography (MRA) of the carotid bifurcation with 2D time-of-flight (TOF) MR angiography with regard to image quality and duration of examination. Materials and Methods: Gadolinium contrast was administered intravenously during 3D MR imaging at 1.5 Tesla in 46 patients presenting with suspected carotid occlusive disease. 2D time-of-flight MR angiography of the carotid bifurcation had been performed in each patient prior to gadolinium-enhanced MR angiography. Results: Gadolinium MRA eliminated slice misregistration and in-plane saturation artifacts that occasionally degrades 2D TOF MR angiography. Gadolinium MRA required less than 4 min to image from the aortic arch to the skull base compared to 11 min for 2D TOF with comparable signal- to-noise ratio (SNR). Postprocessing was required to eliminate overlapping venous enhancement. Both techniques had susceptibility related artifactual loss of signal at the skull base and both demonstrated a linear artifact paralleling the long axis of arteries. Conclusion: Gadolinium-enhanced MR angiography is a promising technique for the evaluation of patients with carotid occlusive disease because it rapidly images the carotid arteries from the aortic arch to the skull base and eliminates some of the artifacts that degrade 2D TOF MR angiography.",
keywords = "Arteries, MR, Carotid arteries, stenosis or obstruction, Magnetic resonance (MR), contrast enhancement, Magnetic resonance (MR), flow artifact, Magnetic resonance (MR), vascular studies",
author = "Cloft, {Harry J.} and Murphy, {Kieran J.} and Prince, {Martin R.} and Brunberg, {James A}",
year = "1996",
doi = "10.1016/0730-725X(96)00091-4",
language = "English (US)",
volume = "14",
pages = "593--600",
journal = "Magnetic Resonance Imaging",
issn = "0730-725X",
publisher = "Elsevier Inc.",
number = "6",

}

TY - JOUR

T1 - 3D gadolinium-enhanced MR angiography of the carotid arteries

AU - Cloft, Harry J.

AU - Murphy, Kieran J.

AU - Prince, Martin R.

AU - Brunberg, James A

PY - 1996

Y1 - 1996

N2 - Purpose: To compare gadolinium-enhanced magnetic resonance angiography (MRA) of the carotid bifurcation with 2D time-of-flight (TOF) MR angiography with regard to image quality and duration of examination. Materials and Methods: Gadolinium contrast was administered intravenously during 3D MR imaging at 1.5 Tesla in 46 patients presenting with suspected carotid occlusive disease. 2D time-of-flight MR angiography of the carotid bifurcation had been performed in each patient prior to gadolinium-enhanced MR angiography. Results: Gadolinium MRA eliminated slice misregistration and in-plane saturation artifacts that occasionally degrades 2D TOF MR angiography. Gadolinium MRA required less than 4 min to image from the aortic arch to the skull base compared to 11 min for 2D TOF with comparable signal- to-noise ratio (SNR). Postprocessing was required to eliminate overlapping venous enhancement. Both techniques had susceptibility related artifactual loss of signal at the skull base and both demonstrated a linear artifact paralleling the long axis of arteries. Conclusion: Gadolinium-enhanced MR angiography is a promising technique for the evaluation of patients with carotid occlusive disease because it rapidly images the carotid arteries from the aortic arch to the skull base and eliminates some of the artifacts that degrade 2D TOF MR angiography.

AB - Purpose: To compare gadolinium-enhanced magnetic resonance angiography (MRA) of the carotid bifurcation with 2D time-of-flight (TOF) MR angiography with regard to image quality and duration of examination. Materials and Methods: Gadolinium contrast was administered intravenously during 3D MR imaging at 1.5 Tesla in 46 patients presenting with suspected carotid occlusive disease. 2D time-of-flight MR angiography of the carotid bifurcation had been performed in each patient prior to gadolinium-enhanced MR angiography. Results: Gadolinium MRA eliminated slice misregistration and in-plane saturation artifacts that occasionally degrades 2D TOF MR angiography. Gadolinium MRA required less than 4 min to image from the aortic arch to the skull base compared to 11 min for 2D TOF with comparable signal- to-noise ratio (SNR). Postprocessing was required to eliminate overlapping venous enhancement. Both techniques had susceptibility related artifactual loss of signal at the skull base and both demonstrated a linear artifact paralleling the long axis of arteries. Conclusion: Gadolinium-enhanced MR angiography is a promising technique for the evaluation of patients with carotid occlusive disease because it rapidly images the carotid arteries from the aortic arch to the skull base and eliminates some of the artifacts that degrade 2D TOF MR angiography.

KW - Arteries, MR

KW - Carotid arteries, stenosis or obstruction

KW - Magnetic resonance (MR), contrast enhancement

KW - Magnetic resonance (MR), flow artifact

KW - Magnetic resonance (MR), vascular studies

UR - http://www.scopus.com/inward/record.url?scp=0029958394&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029958394&partnerID=8YFLogxK

U2 - 10.1016/0730-725X(96)00091-4

DO - 10.1016/0730-725X(96)00091-4

M3 - Article

VL - 14

SP - 593

EP - 600

JO - Magnetic Resonance Imaging

JF - Magnetic Resonance Imaging

SN - 0730-725X

IS - 6

ER -